Unit of competency Outline
Date retreived
24/07/2026 1:16 AM AWST
24/07/2026 1:16 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Assist with coal seam gas control
Assist with coal seam gas control
Unit of competency
National Code
RIIOGD206A
RIIOGD206A
State Code
WB205
WB205
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
21/01/2011
Field of Education
030717 - Plant And Machine Operations
Original Release Date
21/01/2011
Nominal Hours
20
Description
This unit covers assisting with coal seam gas control in the drilling industry. It includes planning and preparing for and assisting with coal seam gas control activities, and monitoring and reporting safety issues.
Notes
Elements and Performance Criteria
1. Plan and prepare for assisting with coal seam gas control
- 1.1. Access, interpret and apply compliance documentation relevant to the work activity
- 1.2. Obtain, confirm and apply work instructions for the allocated task
- 1.3. Resolve coordination requirements with others at the site prior to commencing and during work activities
2. Assist with coal seam gas control activities
- 2.1. Monitor flows and returns for correct volumes and rates, and report inconsistencies to Driller
- 2.2. Assist in operation of coal seam gas control pumps
- 2.3. Read and interpret measuring devices to monitor correct operation of coal seam gas control process and equipment
- 2.4. Communicate operational activities and information to other crew during coal seam gas control operations
- 2.5. Assist in installation and maintenance of equipment
- 2.6. Participate in emergency drills and exercises
3. Monitor and report safety issues
- 3.1. Identify, address and report hazards associated with coal seam gas control under varying working conditions
- 3.2. Recognise kick indicators and advise Driller during coal seam gas control operations
- 3.3. Identify and report ignition sources
- 3.4. Identify and report sources and presence of flammable gases and emissions
- 3.5. Identify and report running coal seam gas control equipment malfunctions
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Relevant compliance documentation may include:
legislative, organisational and site requirements and procedures
manufacturer's guidelines and specifications
Australian standards
code of practice
Employment and workplace relations legislation
Equal Employment Opportunity and Disability Discrimination legislation
Work instructions may come from briefings, handovers, plans and work orders and may be written or verbal, formal or informal and may include:
nature and scope of tasks
specifications
quality of finished works
achievement targets
operational conditions
obtaining of permits required
site layout
out of bounds areas
worksite inspection requirements
lighting conditions
plant or equipment defects
hazards and potential hazards
coordination requirements or issues
contamination control requirements
environmental control requirements
barricade and signage requirements
Coordination requirements may include
drill team
other equipment operators
maintenance personnel
supervisors
worksite personnel
Measuring devices may include:
2-way radio
hand signals
telephone
public address system
written work instructions
Drills and exercises may include:
pit drill
trip drill
abandonment drill
evacuation
Hazards may include:
blow out gas to surface
ignition of gas
toxic gases
pressurised coal seam gas system
Working conditions may include:
night time operations
day time operations
hot climates
cold climates
snow
wet weather conditions
high wind
Kick indicators may include:
flow from wells (pump off)
increase in flow from well (pumps on)
pit volume gain
Ignition sources may include:
non-explosion protected devices such as:
electrical connections/leads
rig lights and wiring
flashlights
computers
mobile phones
electronic car keys
charging circuits from solar panels
charging and starting circuits from vehicles
drill rigs
mud pumps
lighting plants
auxiliary equipment
static discharge - lightning
flare stacks
engine exhausts from vehicles, drill rigs, auxiliary equipment
Flammable gases and emissions may include:
methane (CH4)
hydrogen sulphide (H2S)
carbon dioxide (CO2)
carbon monoxide (CO)
Coal seam gas control equipment may include:
mud system
blooie diverter lines
auxiliary equipment
pressure measuring devices
gas detection equipment and devices
diverters
Relevant compliance documentation may include:
legislative, organisational and site requirements and procedures
manufacturer's guidelines and specifications
Australian standards
code of practice
Employment and workplace relations legislation
Equal Employment Opportunity and Disability Discrimination legislation
Work instructions may come from briefings, handovers, plans and work orders and may be written or verbal, formal or informal and may include:
nature and scope of tasks
specifications
quality of finished works
achievement targets
operational conditions
obtaining of permits required
site layout
out of bounds areas
worksite inspection requirements
lighting conditions
plant or equipment defects
hazards and potential hazards
coordination requirements or issues
contamination control requirements
environmental control requirements
barricade and signage requirements
Coordination requirements may include
drill team
other equipment operators
maintenance personnel
supervisors
worksite personnel
Measuring devices may include:
2-way radio
hand signals
telephone
public address system
written work instructions
Drills and exercises may include:
pit drill
trip drill
abandonment drill
evacuation
Hazards may include:
blow out gas to surface
ignition of gas
toxic gases
pressurised coal seam gas system
Working conditions may include:
night time operations
day time operations
hot climates
cold climates
snow
wet weather conditions
high wind
Kick indicators may include:
flow from wells (pump off)
increase in flow from well (pumps on)
pit volume gain
Ignition sources may include:
non-explosion protected devices such as:
electrical connections/leads
rig lights and wiring
flashlights
computers
mobile phones
electronic car keys
charging circuits from solar panels
charging and starting circuits from vehicles
drill rigs
mud pumps
lighting plants
auxiliary equipment
static discharge - lightning
flare stacks
engine exhausts from vehicles, drill rigs, auxiliary equipment
Flammable gases and emissions may include:
methane (CH4)
hydrogen sulphide (H2S)
carbon dioxide (CO2)
carbon monoxide (CO)
Coal seam gas control equipment may include:
mud system
blooie diverter lines
auxiliary equipment
pressure measuring devices
gas detection equipment and devices
diverters
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to worksite operations and satisfy all of the requirements of the performance criteria, required skills and knowledge and the range statement of this unit and include evidence of the following:
knowledge of the requirements, procedures and instructions for assisting with coal seam gas control
implementation of requirements, procedures and techniques for the safe, effective and efficient assisting with coal seam gas control
working with others to undertake and complete coal seam gas control that meets all of the required outcomes
consistent timely provision of assistance with coal seam gas control that safely, effectively and efficiently meets the required outcomes
Context of and specific resources for assessment
This unit must be assessed in the context of the work environment. Where personal safety or environmental damage are limiting factors, assessment may occur in a simulated environment provided it is realistic and sufficiently rigorous to cover all aspects of workplace performance, including task skills, task management skills, contingency management skills and job role environment skills.
The assessment environment should not disadvantage the participant. For example, language, literacy and numeracy demands of assessment should not be greater than those required on the job.
Customisation of assessment and delivery environment to sensitively accommodate cultural diversity.
Aboriginal people and other people from a non English speaking background may have second language issues.
Assessment of this competency requires typical resources normally used in the work environment. Selection and use of resources for particular worksites may differ due to site circumstances.
Where applicable, physical resources should include equipment modified for people with disabilities.
Access must be provided to appropriate learning and/or assessment support when required.
Method of assessment
This unit may be assessed in a holistic way with other units of competency. The assessment strategy for this unit must verify required knowledge and skill and practical application using more than one of the following assessment methods:
written and/or oral assessment of the candidate's required knowledge
observed, documented and/or first hand testimonial evidence of the candidate's:
implementation of appropriate requirement, procedures and techniques for the safe, effective and efficient achievement of required outcomes
consistently achieving the required outcomes
first hand testimonial evidence of the candidate's:
working with others to undertake and complete the coal seam gas control
Guidance information for assessment
Consult the SkillsDMC User Guide for further information on assessment including access and equity issues.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to worksite operations and satisfy all of the requirements of the performance criteria, required skills and knowledge and the range statement of this unit and include evidence of the following:
knowledge of the requirements, procedures and instructions for assisting with coal seam gas control
implementation of requirements, procedures and techniques for the safe, effective and efficient assisting with coal seam gas control
working with others to undertake and complete coal seam gas control that meets all of the required outcomes
consistent timely provision of assistance with coal seam gas control that safely, effectively and efficiently meets the required outcomes
Context of and specific resources for assessment
This unit must be assessed in the context of the work environment. Where personal safety or environmental damage are limiting factors, assessment may occur in a simulated environment provided it is realistic and sufficiently rigorous to cover all aspects of workplace performance, including task skills, task management skills, contingency management skills and job role environment skills.
The assessment environment should not disadvantage the participant. For example, language, literacy and numeracy demands of assessment should not be greater than those required on the job.
Customisation of assessment and delivery environment to sensitively accommodate cultural diversity.
Aboriginal people and other people from a non English speaking background may have second language issues.
Assessment of this competency requires typical resources normally used in the work environment. Selection and use of resources for particular worksites may differ due to site circumstances.
Where applicable, physical resources should include equipment modified for people with disabilities.
Access must be provided to appropriate learning and/or assessment support when required.
Method of assessment
This unit may be assessed in a holistic way with other units of competency. The assessment strategy for this unit must verify required knowledge and skill and practical application using more than one of the following assessment methods:
written and/or oral assessment of the candidate's required knowledge
observed, documented and/or first hand testimonial evidence of the candidate's:
implementation of appropriate requirement, procedures and techniques for the safe, effective and efficient achievement of required outcomes
consistently achieving the required outcomes
first hand testimonial evidence of the candidate's:
working with others to undertake and complete the coal seam gas control
Guidance information for assessment
Consult the SkillsDMC User Guide for further information on assessment including access and equity issues.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| WH512 | RIIOGD206D | Assist with coal seam gas control | Unit of competency |