Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Fault find and repair off-grid photovoltaic/generating set systems to an electrical installation

Fault find and repair off-grid photovoltaic/generating set systems to an electrical installation

Unit of competency
National Code
UEERE0071
State Code
OEU40
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
20/12/2022
State Implementation and Classification
Approved Date
16/03/2023
Field of Education
031399 - Electrical And Electronic Engineering And Technology, N.e.c.
Original Release Date
16/03/2023
Nominal Hours
27
Description
This unit involves the skills and knowledge required to fault find and repair off-grid photovoltaic (PV)/generating set (genset) systems to an electrical installation.It includes preparing to work on off grid systems, solving problems in off grid systems and completing work and documenting problem-solving activities.The skills and knowledge described in this unit require a licence or permit to practice in the workplace where work is carried out on electrical installations, which are designed to operate at voltages greater than 50 volt (V) alternating current (a.c.) or 120 V direct current (d.c).Competency development activities in this unit are subject to regulations directly related to licensing. Where a licence or permit to practice is not held, a relevant contract of training, such as an Australian Apprenticeship, is required.Additional and/or other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Notes
Elements and Performance Criteria
1 Prepare to fault find and repair off-grid PV/genset systems
  • 1.1 Work health and safety (WHS)/occupational health and safety (OHS) processes and procedures for relevant work area are identified and applied in accordance with workplace procedures
  • 1.2 The nature of the fault/issue is identified from stakeholders and relevant data and documentation
  • 1.3 Requirements for working with other stakeholders are confirmed and applied
  • 1.4 Required materials, tools, apparatus and testing devices are identified, accessed and checked for correct operation and safety
  • 1.5 Need to test or measure live electrical work is determined in accordance with WHS/OHS requirements and workplace procedures
2 Fault find and repair off-grid PV/genset systems
  • 2.1 Circuits/apparatus are isolated in accordance with WHS/OHS requirements and workplace procedures
  • 2.2 Nature of reported fault/issue is verified
  • 2.3 System testing is conducted and documented
  • 2.4 Fault or faults are diagnosed, faulty equipment is identified, and the replacement products required are documented
  • 2.5 System is made safe, faulty apparatus is dismantled, recorded and stored in accordance with manufacturer guides and stakeholder instructions
  • 2.6 Repaired or replaced apparatus is assembled in accordance with manufacturer guidelines, industry standards and regulation
3 Complete and report repair work activities
  • 3.1 Repaired apparatus is tested and commissioned in accordance with manufacturer guidelines, industry standards and regulation
  • 3.2 Work area is cleaned and made safe
  • 3.3 Repair is documented and stakeholders notified
No information
No information
No information