Unit of competency Outline

Date retreived
22/07/2026 6:19 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Maintain and repair multi stage, cascade and/or ultra-cold industrial refrigeration systems

Maintain and repair multi stage, cascade and/or ultra-cold industrial refrigeration systems

Unit of competency
National Code
MEM18091B
State Code
W5628
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
2.00
Current Release Date
16/03/2012
State Implementation and Classification
Approved Date
11/09/2006
Field of Education
031315 - Refrigeration And Air Conditioning Mechanics
Original Release Date
11/09/2006
Nominal Hours
36
Description
This unit covers maintaining and repairing multi stage, cascade cryogenic and ultra-cold industrial refrigeration systems.
Notes
Elements and Performance Criteria
1. Undertake preventive maintenance checks/adjustment on multi stage, cascade and/or ultra-cold industrial refrigeration systems
  • 1.1. The temperature, pressure and properties of the multi stage, cascade and/or ultra-cold refrigeration system are checked for conformance to specification.
  • 1.2. The noise/vibration levels of the multi stage, cascade and/or ultra-cold refrigeration system are checked for conformance to specification.
  • 1.3. Preventative maintenance tasks are performed according to manufacturers' specifications using refrigeration techniques/practices.
2. Undertake fault finding on multi stage, cascade and/or ultra-cold industrial refrigeration systems and components
  • 2.1. System components are identified correctly.
  • 2.2. The characteristics and operation of each component is understood.
  • 2.3. The operational function of each component is inspected and tested.
  • 2.4. Correct operation of each component is assessed against specification.
3. Repair/replace faulty components
  • 3.1. Faulty components are localised and malfunction is confirmed by inspection and testing using industrial refrigeration principles, procedures and safety requirements.
  • 3.2. The refrigerant is removed safely from the system and contained in accordance with standard operating procedures and regulatory requirements where appropriate.
  • 3.3. Faulty components are dismantled and repaired to manufacturers' specifications as required
  • 3.4. Replacement parts are selected from manufacturers' catalogues according to required specifications.
4. Return to service multi stage, cascade and/or ultra-cold refrigeration systems
  • 4.1. Components are reassembled and tested for correct operation and assessed against specification.
  • 4.2. The system is charged with correct refrigerant safely and in accordance with standard operating procedures and regulatory requirements where appropriate.
  • 4.3. Using industrial refrigeration principles and system application techniques, correct operation of the equipment is verified.
  • 4.4. Maintenance records/service reports are completed by appropriate designated means.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Preventative maintenance tasks
Check/adjust fan belts, check/clean filters, check/clean heat exchangers (evaporator and condenser), overhaul of major system components, cleaning of major system components, testing operation of all safety devices
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to maintain and repair multi stage, cascade and/or ultra-cold industrial refrigeration systems. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with the maintenance and repair of multi stage, cascade cryogenic and ultra-cold industrial refrigeration systems, or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
Replaced By
State Code National Code Title Type
OAU38 MEM18091 Maintain and repair multistage, cascade and/or ultra-cold industrial refrigeration systems Unit of competency