Unit of competency Outline

Date retreived
23/07/2026 1:17 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Prepare and install architectural engineered glazing

Prepare and install architectural engineered glazing

Unit of competency
National Code
LMFGG3018B
State Code
W8692
TGA Status
Deleted
DTWD Status
Deleted
Current Release Number
1.00
Current Release Date
11/05/2009
State Implementation and Classification
Approved Date
30/09/2008
Field of Education
040323 - Glazing
Original Release Date
30/09/2008
Nominal Hours
60
Description
This unit addresses the knowledge and skills required to prepare and install glass in structural and other architectural engineered applications.
Notes
Elements and Performance Criteria
1. Identify work requirements
  • 1.1. Work requirements in the form of type of glass, frames and the method of fixing are identified from work instructions
  • 1.2. Workplace health and safety requirements for fabrication and installation of architectural engineered glazing, including personal protection needs, are identified and observed throughout the work
  • 1.3. The process for fabricating and installing architectural engineered glazing is identified
2. Prepare for work
  • 2.1. Work sequence is planned in a logical order to suit the job
  • 2.2. Tools, equipment and materials, other than glass and frames, are selected and checked prior to use to ensure that they are appropriate for the work, serviceable and in a safe condition
  • 2.3. Type of glass to be fitted and frames are selected to match:
  • 2.3.1. customer order
  • 2.3.2. requirements for security, noise or light control
  • 2.3.3. relevant Australian Standard
  • 2.4. Glass is checked for type, size and imperfections
  • 2.5. Glass fixing method is selected according to:
  • 2.5.1. specification
  • 2.5.2. type of glass and frame
  • 2.5.3. security requirements
  • 2.5.4. sealing methods
  • 2.5.5. relevant Australian Standard
  • 2.6. Frame or opening is prepared to receive glass by:
  • 2.6.1. cleaning
  • 2.6.2. surface preparation (if required)
  • 2.6.3. checking size against specification
  • 2.7. Fixing and sealing materials are prepared by mixing or cutting to length as appropriate
3. Identify site conditions and restraints
  • 3.1. Site safety hazards are recognised and corrective action taken to reduce injury to self and others
  • 3.2. Any on-site difficulties are identified and addressed in accordance with regulations and enterprise agreements
  • 3.3. Special characteristics of the glass aperture are identified in relation to the effect of the glass fitting process on the finished job
  • 3.4. Covering material is applied where necessary to protect existing fixtures and fittings
4. Fit glass
  • 4.1. Glass is fixed to the frame or opening using the selected method and in accordance with recognised Australian and industry standards
  • 4.2. Solvents and sealants are used in accordance with manufacturer recommendations and Australian Standards
  • 4.3. Excess sealing material is removed
  • 4.4. Glass and/or frame are cleaned after fixing
5. Inspect final product and clean up work area
  • 5.1. Completed installation is checked to ensure compliance with customer requirements, specifications and Australian Standards
  • 5.2. Workplace documentation is completed in accordance with workplace requirements
  • 5.3. Work area is cleaned and left in a safe condition and rubbish removed from work area and disposed of in accordance with relevant statutory requirements and enterprise requirements
  • 5.4. Tools, equipment and materials are cleaned and stored following workplace procedures
  • 5.5. Waste and scrap material is removed for disposal or recycling as required
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Unit context
Work requires individuals to demonstrate discretion, judgement and problem solving skills in the planning and fitting of glass in structural and other architectural engineered applications
Work is carried out in accordance with statutory requirements, environment legislation, manual handling procedures and relevant regulations and organisation insurance requirements
OHS requirements may include legislation, standards, building codes, material safety management systems and local safe operating procedures
Tools and equipment may include:
general cutting and glazing tools
electric and pneumatic portable power tools
saws
drills and portable compressors
Materials are to include but are not limited to:
all forms of flat glass and acrylic glazing products
plastic
aluminium
steel
solid timber
gaskets
sealants and adhesives
Types of glass may include but are not limited to:
annealed glass
toughened glass
laminated glass
wired glass
bandit resistant glass
bullet resistant glass
heat reflective glass
solar controlled glass and spandral panels
Methods of glazing may include:
beaded
pocket
flush
channel glazing and structural glazing
Personal protective equipment
Personal protective equipment is to include that prescribed under legislation, regulation and enterprise policies and practices. It may include:
gauntlets
gloves
safety glasses
hard hats
safety footwear
aprons and overalls
Information and procedures
Workplace procedures relating to fitting of glass for structural applications
On-site procedures and regulations relating to the handling and movement of glass
Equipment manufacturers' specifications and operational procedures
Work instructions including job sheets, plans, drawings and designs
Safety standards include personal protective equipment, OHS regulations and enterprise requirements
Australian Standards:
AS1288 Glass in buildings, selection and installation
AS2088 Safety glazing materials in buildings
AS4667 Quality requirements for cut to size and processed glass
AS4285 Skylights
AS4666 Insulating glass units
EVIDENCE GUIDE
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.

Critical aspects of evidence
Interpret work order/job instruction and locate and apply relevant information to fabricate and install structural glazing
Apply safe handling requirements for equipment, products and materials, including use of personal protective equipment
Follow work instructions, operating procedures and inspection practices to:
minimise the risk of injury to self and others
prevent damage to goods, equipment and products
maintain required production output and product quality
To complete a minimum of:
measure glass for curtain walls, balustrades, suspended and overhead glazing
select glass to comply with AS1288
cut and process glass in accordance with AS4667
identify and erect appropriate ladders and scaffolding to comply with the relevant regulations and standards
identification and application of glazing, structural sealants and tapes
install glazing materials and weatherproofing
calculate the cost of glass and labour
Work effectively with others
Modify activities to cater for variations in workplace contexts and environment

Resource implications
Frames, glass, fixing material, sealants, workplace operating procedures and work orders, personal protective equipment and an appropriate work area/site.

Method of assessment
Assessment methods must confirm consistency of performance over time and in a range of workplace relevant contexts.
Assessment should be by direct observation of tasks and questioning on underpinning knowledge.
Assessment may be in conjunction with assessment of other relevant units of competency.

Context of assessment
Assessment may occur on the job or in a workplace simulated facility with relevant fabrication and installation equipment, materials, work instructions and deadlines.
Replaces
State Code National Code Title Type
W0339 LMFGG3018A Prepare and install architectural engineered glazing Unit of competency
Replaced By
State Code National Code Title Type
S7834 LMFGG3018C Prepare and install architectural engineered glazing Unit of competency
State Code National Code Title Type
W034 LMF30602 Certificate III in Glass and Glazing Qualification