Unit of competency Outline
Date retreived
22/07/2026 11:48 PM AWST
22/07/2026 11:48 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Diagnose and rectify faults in camera circuits and equipment
Diagnose and rectify faults in camera circuits and equipment
Unit of competency
National Code
UEEEC0022
UEEEC0022
State Code
OBZ01
OBZ01
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031317 - Electronic Equipment Servicing
Original Release Date
12/07/2021
Nominal Hours
54
Description
This unit involves the skills and knowledge required to diagnose and rectify faults in camera circuits and equipment.It includes fault finding and repairing faults in camera circuits and equipment. It also includes working safely, applying logical diagnostic methods of camera circuit components, rectifying faults, safety and functional testing, and completing the necessary service documentation.Permits may be required for some work environments, such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to diagnose and rectify camera circuits and equipment faults
- 1.1 Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are identified and applied
- 1.2 WHS/OHS risk control measures and workplace procedures are followed in preparation for camera circuits and equipment work
- 1.3 Safety hazards that have not previously been identified are risk assessed, documented and risk control measures devised and implemented in consultation with appropriate person/s
- 1.4 Extent of faults is determined from reports, documentation and discussions with appropriate person/s
- 1.5 Appropriate person/s is consulted to ensure the camera circuits and equipment work is coordinated effectively with others involved on the worksite
- 1.6 Tools, equipment and testing devices needed to diagnose faults are obtained in accordance with workplace procedures and checked for correct operation and safety
2 Diagnose and rectify camera circuits and equipment faults
- 2.1 WHS/OHS risk control measures and workplace procedures for carrying out camera circuits and equipment work are followed
- 2.2 Need to test and measure live work is determined in accordance with WHS/OHS requirements and, as required, conducted within workplace safety procedures
- 2.3 Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
- 2.4 Logical diagnostic methods are applied to diagnose camera circuit faults using measurements of circuit operating parameters in accordance with camera operating specifications
- 2.5 Suspected fault scenarios are tested as being the source of camera circuit problems
- 2.6 Faults in the electronic components of the camera circuits are rectified to camera circuits operation and industry standards
- 2.7 Circuits are inspected and tested to verify that the camera operates to specified requirements
- 2.8 Unplanned situations are responded to in accordance with workplace procedures, discussions with appropriate person/s and consistent with job specifications and requirements in a manner that minimises risk to personnel and equipment
- 2.9 Diagnosis and rectification activities are carried out efficiently without waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices
3 Complete and report fault diagnosis and rectification activities
- 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
- 3.2 Worksite is made safe in accordance with workplace safety procedures
- 3.3 Rectification of faults is documented in accordance with workplace procedures
- 3.4 Appropriate person/s is notified in accordance with workplace procedures that camera circuit faults have been rectified
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WC603 | UEENEEH178A | Diagnose and rectify faults in camera circuits and equipment | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BFP4 | UEE40720 | Certificate IV in Electronics and Communications | Qualification |
| BFQ2 | UEE60220 | Advanced Diploma of Electronics and Communications Engineering | Qualification |
| BFP5 | UEE50520 | Diploma of Electronics and Communications Engineering | Qualification |
| BFJ6 | UEE61720 | Advanced Diploma of Engineering Technology - Electronics | Qualification |
| BFO3 | UEE41720 | Certificate IV in Rail - Communications and Network Systems | Qualification |
| BFN7 | UEE41520 | Certificate IV in Video and Audio Systems | Qualification |