Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Conduct periodic maintenance of remote area power supply wind generators

Conduct periodic maintenance of remote area power supply wind generators

Unit of competency
National Code
UEERE0009
State Code
OBX45
TGA Status
Current
DTWD Status
Approved
Current Release Number
2.00
Current Release Date
14/10/2021
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031311 - Powerline Installation And Maintenance
Original Release Date
12/07/2021
Nominal Hours
36
Description
This unit involves the skills and knowledge required to conduct periodic maintenance of remote area power supply (RAPS) wind generators where the exposed voltage is not greater than 50 volt (V) alternating current (a.c.) or 120 V direct current (d.c).It includes preparing for, completing and reporting on maintenance of RAPS wind generators.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to conduct periodic maintenance on wind generators
  • 1.1 Work health and safety (WHS)/occupational health and safety (OHS) procedures for a RAPS plant are identified and applied in accordance with workplace procedures
  • 1.2 Risk control measures are applied in accordance with workplace procedures prior to commencing work
  • 1.3 Risks/hazards are identified, assessed, reported to relevant person/s and control measures implemented
  • 1.4 Nature and location of RAPS system is identified from relevant documentation or from relevant person/s to determine the scope of work
  • 1.5 Instructions for coordinating work with relevant personnel and the local community is obtained from relevant person/s and applied
  • 1.6 Materials required for the work are identified and accessed in accordance with workplace procedures
  • 1.7 Tools, equipment and testing devices required for work are obtained and checked for correct operation and safety
2 Maintain RAPS systems wind generators
  • 2.1 Workplace risk control measures and procedures are applied
  • 2.2 Need to test or measure live electrical work is determined in accordance with WHS/OHS requirements and conducted in accordance with workplace procedures
  • 2.3 Circuits/machines/plant are isolated in strict accordance with WHS/OHS requirements and workplace procedures
  • 2.4 RAPS system wind generators are tested in accordance with relevant workplace procedures
  • 2.5 Wind generator maintenance, including performance measurements and repairs, is completed safely in accordance with workplace routines and procedures
  • 2.6 Known types of wind generator functional faults are identified using fault-finding procedures
  • 2.7 Non-routine events are referred to relevant person/s for directions in accordance with workplace procedures
  • 2.8 Maintenance and repair work are completed minimising waste of materials, energy, damage to apparatus, circuits, the surrounding environment and services
  • 2.9 Quality checks are conducted in accordance with workplace procedures
3 Complete maintenance work of wind generators and report outcomes
  • 3.1 Workplace risk control measures and procedures are applied
  • 3.2 Worksite is cleaned and made safe in accordance with workplace procedures
  • 3.3 Maintenance issues are referred to the local community in accordance with workplace procedures
  • 3.4 Wind generator performance measurements are reported to relevant person/s in accordance with maintenance reporting procedures
No information
No information
Replaces
State Code National Code Title Type
WC680 UEENEEK106A Conduct periodic maintenance of remote area power supply wind generators Unit of competency