Unit of competency Outline

Date retreived
22/07/2026 11:06 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Process body fluid specimens using a point of care testing device

Process body fluid specimens using a point of care testing device

Unit of competency
National Code
MSL974036
State Code
OEX79
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
20/12/2022
State Implementation and Classification
Approved Date
24/05/2023
Field of Education
019909 - Laboratory Technology
Original Release Date
24/05/2023
Nominal Hours
70
Description
This unit describes the skills and knowledge required to complete pre-analytics, analyse body fluid specimens, record results and maintain a point of care testing (PoCT) device.This unit applies to operators who follow workplace procedures and apply quality systems to analyse body fluid specimens after the initial collection process. It is relevant to operators working directly with clients and those working in laboratories. The unit relates to diagnostic PoCT devices that provide an electronic read-out such as those used for measuring glucose, blood gases and haematological or biochemical parameters as well as devices used for toxicology, dipstick, test strip or lateral flow testing and other simple manual devices. No licensing or certification requirements exist at the time of publication. However, regulations and/or external accreditation requirements for laboratory operations exist, so local requirements should be checked. Relevant legislation, industry standards and codes of practice within Australia must also be applied.
Notes
Elements and Performance Criteria
1. Complete pre-analytics
  • 1.1 Confirm correct patient identification in accordance with workplace procedures
  • 1.2 Identify collection method and confirm specimen type has been approved for testing based on manufacturer requirements and workplace procedures
  • 1.3 Recognise and reject specimens that do not meet specimen quality requirements
2. Prepare and operate PoCT device
  • 2.1 Prepare PoCT device for operation in accordance with workplace procedures
  • 2.2 Follow workplace procedures for traceability of operator and patient
  • 2.3 Maintain test integrity through appropriate handling of consumables
  • 2.4 Perform tests in accordance with workplace procedures and personal protective equipment (PPE) requirements for infection prevention
  • 2.5 Dispose of waste in accordance with workplace procedures
  • 2.6 Identify and troubleshoot result flags and errors in accordance with workplace procedures
  • 2.7 Identify and report device errors that are outside area of responsibility and refer to designated person, providing relevant supporting information
3. Review and document results
  • 3.1 Review results against reference intervals and reportable range
  • 3.2 Identify abnormal, clinically urgent and erroneous results, taking action in accordance with workplace procedures
  • 3.3 Accurately record results in accordance with workplace procedures
4. Maintain device readiness
  • 4.1 Clean and decontaminate devices in accordance with workplace procedures
  • 4.2 Identify, address and document minor device maintenance tasks in accordance with workplace procedures
  • 4.3 Identify stock stability and storage requirements, taking any actions that result in maintenance of stock availability and integrity
  • 4.4 Perform routine quality-control tests in accordance with workplace procedures
No information
No information
Replaces
State Code National Code Title Type
OBP05 MSL974030 Process body fluid specimens using a point of care testing device Unit of competency