Unit of competency Outline
Date retreived
22/07/2026 9:21 PM AWST
22/07/2026 9:21 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Maintain Type A gas appliances
Maintain Type A gas appliances
Unit of competency
National Code
CPCPGS3022A
CPCPGS3022A
State Code
D7459
D7459
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
11/10/2011
Field of Education
040327 - Plumbing
Original Release Date
11/10/2011
Nominal Hours
8
Description
This unit of competency specifies the outcomes required to perform basic maintenance on Type A gas appliances.
Notes
Elements and Performance Criteria
1. Prepare for work.
- 1.1. Appliance specifications and servicing and manufacturer manuals are obtained for planned work activity.
- 1.2. Safety (OHS) requirements associated with maintenance of Type A gas appliances, and workplace environmental requirements, are adhered to throughout the work.
- 1.3. Quality assurance requirements for company operations are identified and adhered to.
- 1.4. Tools and equipment are selected consistent with maintaining Type A gas appliances, checked for serviceability, and any faults are reported to supervisor.
- 1.5. Tasks are planned in conjunction with others involved in or affected by the work.
- 1.6. Work area is prepared and materials identified to support the efficient conduct of maintenance of Type A gas appliances.
2. Identify maintenance requirements.
- 2.1. Appliance is checked to ensure installation complies with standards and manufacturer requirements.
- 2.2. Electrical safety check is carried out in accordance with authorities' procedures and data is recorded in format required by job specification.
- 2.3. Test equipment is used to support visual inspection and to conduct testing in accordance with statutory and regulatory authority requirements.
3. Conduct maintenance.
- 3.1. Maintenance tasks are carried out in accordance with specifications and manufacturer requirements.
- 3.2. Appliances are checked for operation in accordance with specifications, standards and manufacturer recommendations.
- 3.3. Faults and malfunctions are identified and reported in accordance with workplace requirements.
4. Clean up.
- 4.1. Work area is cleared and materials disposed of or recycled in accordance with state and territory legislation and workplace procedures.
- 4.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.
- 4.3. Information is accessed and documentation completed in accordance with workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Type A gas appliances:
are badged appliances of less than 500 megajoules (MJ) for which an Australian Gas Authority (AGA) approval scheme exists
include:
decorative heaters
ducted heating systems
gas stoves and hot plates
heated water storage
instant heated water heaters
space heaters.
Environmental requirements include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Tools and equipment may include:
chain blocks
forklifts
hand and power tools
hand trolleys
hoists and jacks
lifting and load shifting equipment
measuring equipment
rollers
spanners
test equipment and instruments, including:
manometers
multi-meters
neon testers
volt sticks
wrenches.
Maintenance of Type A gas appliances:
includes cleaning or adjusting gas components, including:
burners
pilots
regulators
thermocouples
thermostats
temperature and pressure relief (TPR) valves
also includes rectifying simple gas supply problems, including meters and regulators
is to comply with appropriate Australian standards.
Materials for the maintenance of Type A gas appliances:
may include:
piping materials
regulators and meters
Type A gas appliances
other approved materials
are to comply with appropriate standards for maintaining Type A gas appliances.
Statutory and regulatory authorities include:
state or territory statutory authority
statutory gasfitting authority
statutory plumbing authority.
Information may include:
charts and hand drawings
diagrams, sketches or graphics
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
maps
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing and gasfitting authority regulations
relevant Australian standards
safe work procedures relating to maintaining Type A gas appliances
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Type A gas appliances:
are badged appliances of less than 500 megajoules (MJ) for which an Australian Gas Authority (AGA) approval scheme exists
include:
decorative heaters
ducted heating systems
gas stoves and hot plates
heated water storage
instant heated water heaters
space heaters.
Environmental requirements include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Tools and equipment may include:
chain blocks
forklifts
hand and power tools
hand trolleys
hoists and jacks
lifting and load shifting equipment
measuring equipment
rollers
spanners
test equipment and instruments, including:
manometers
multi-meters
neon testers
volt sticks
wrenches.
Maintenance of Type A gas appliances:
includes cleaning or adjusting gas components, including:
burners
pilots
regulators
thermocouples
thermostats
temperature and pressure relief (TPR) valves
also includes rectifying simple gas supply problems, including meters and regulators
is to comply with appropriate Australian standards.
Materials for the maintenance of Type A gas appliances:
may include:
piping materials
regulators and meters
Type A gas appliances
other approved materials
are to comply with appropriate standards for maintaining Type A gas appliances.
Statutory and regulatory authorities include:
state or territory statutory authority
statutory gasfitting authority
statutory plumbing authority.
Information may include:
charts and hand drawings
diagrams, sketches or graphics
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
maps
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing and gasfitting authority regulations
relevant Australian standards
safe work procedures relating to maintaining Type A gas appliances
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements and maintain Type A gas appliances
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, perform cleaning and routine basic adjustment to two Type A appliances, checking gas supply pressures, effective operation and flue condition, ensuring:
correct identification of maintenance procedures and requirements
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements and maintain Type A gas appliances
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, perform cleaning and routine basic adjustment to two Type A appliances, checking gas supply pressures, effective operation and flue condition, ensuring:
correct identification of maintenance procedures and requirements
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W9697 | CPCPGS3012A | Size consumer gas piping systems | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| WF899 | CPCPGS3052A | Maintain Type A gas appliances | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| D414 | CPC32711 | Certificate III in Gas Fitting | Qualification |