Unit of competency Outline

Date retreived
23/07/2026 1:35 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Diagnose and rectify batteries, low voltage sensors and circuits

Diagnose and rectify batteries, low voltage sensors and circuits

Unit of competency
National Code
MEM27006
State Code
OAT32
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
26/06/2019
State Implementation and Classification
Approved Date
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
Nominal Hours
72
Description
This unit of competency defines the skills and knowledge required to use test instruments, test the battery, assess and rectify wiring faults.It applies to testing and rectification activities associated with 12, 24 36 and 48 volt wiring systems on vehicles, mobile plant and stationary equipment.Where soldering of wires/connections is required unit MEM05001 Perform manual soldering/desoldering - electrical/electronic components should also be selected.Where an electrical wiring system is above 48 volts unit MEM18045 Fault find and repair electrical equipment/components up to 250 volts single phase supply or unit MEM18046 Fault find and repair electrical equipment/components up to 1000 volts a.c./1500 volts d.c. should also be selected as appropriate.No licensing, legislative or certification requirements apply to this unit at the time of publication.Band: AUnit Weight: 8
Notes
Elements and Performance Criteria
1 Determine job requirements
  • 1.1 Follow standard operating procedures (SOPs)
  • 1.2 Comply with work health and safety (WHS) requirements at all times
  • 1.3 Use appropriate personal protective equipment (PPE) in accordance with SOPs
  • 1.4 Identify job requirements from specifications, drawings, job sheets or work instructions
2 Use test instruments
  • 2.1 Apply principles of electron theory, current, voltage and resistance to diagnose and rectify low voltage electrical systems
  • 2.2 Select, use and maintain appropriate test instruments to determine current, voltage and resistance
  • 2.3 Interpret electrical drawings and manufacturer diagrams
  • 2.4 Determine series, parallel and series parallel circuits
  • 2.5 Interpret and apply basic electrical laws
  • 2.6 Connect amps voltage and resistance (AVR) test instruments into circuits to measure current, voltage and resistance
  • 2.7 Read meters to standard accuracy
  • 2.8 Use and apply multipliers and shunts
3 Test battery
  • 3.1 Interpret and apply chemical battery operating principles when testing batteries
  • 3.2 Determine electrolyte level and record specific gravity readings temperature
  • 3.3 Carry out dry charge preparation and recharging of batteries
  • 3.4 Perform discharge testing according to prescribed procedures
  • 3.5 Select replacement batteries for application
4 Assess and rectify wiring faults
  • 4.1 Isolate wiring and sensor fault
  • 4.2 Determine replacement sensors and cables/wires, including size and insulation quality
  • 4.3 Make up wiring looms for application and securely fix
  • 4.4 Strip, fit, prepare and terminate wiring and cables
  • 4.5 Test terminated cables for continuity and to comply with requirements
  • 4.6 Remove corrosion, neutralise and apply appropriate protective coating
  • 4.7 Test sensors, relays, solenoids, contacts and circuits and repair/replace
No information
No information
Replaces
State Code National Code Title Type
W5575 MEM18030B Diagnose and rectify low voltage electrical systems Unit of competency