Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Diagnose and maintain electronic controlling systems on mobile plant

Diagnose and maintain electronic controlling systems on mobile plant

Unit of competency
National Code
MEM18047B
State Code
W5592
TGA Status
Replaced
DTWD Status
Transition (Replaced)
Current Release Number
1.00
Current Release Date
01/12/2005
State Implementation and Classification
Approved Date
11/09/2006
Field of Education
031317 - Electronic Equipment Servicing
Original Release Date
11/09/2006
Nominal Hours
36
Description
This unit covers testing, diagnosing and maintaining electronic control systems. Path 1
Notes
Elements and Performance Criteria
1. Access and interpret fault codes
  • 1.1. Applicable control unit is located and identified.
  • 1.2. Fault codes are accessed using vehicle indicators, meters and diagnostic tooling.
  • 1.3. Fault codes are interpreted.
  • 1.4. Fault codes are cleared from memory according to procedures.
  • 1.5. Diagnostic and maintenance procedures are performed using applicable techniques and precautions to safeguard electronic components and systems.
2. Locate and rectify faults using fault codes and manufactures fault finding and rectification procedures
  • 2.1. Fault is traced from fault codes using applicable troubleshooting procedures.
  • 2.2. Faults are rectified to required specification.
3. Locate and test input components
  • 3.1. Input components are located and identified.
  • 3.2. Input components are electrically tested.
4. Locate and test output components
  • 4.1. Output components are located and identified.
  • 4.2. Output components electrically tested.
5. Remove/replace and adjust sensors and actuators
  • 5.1. Component part is removed correctly.
  • 5.2. Correct replacement part is identified.
  • 5.3. Component part replaced correctly.
  • 5.4. Adjustments are made in relation to mechanical clearances and measured electrical and resistance values.
6. Change operating parameters
  • 6.1. Appropriate specifications are sourced from plant/equipment identification and applicable manuals and specifications.
  • 6.2. Appropriate tooling (software/hardware) is selected.
  • 6.3. Plant/equipment identification is used to obtain security codes.
  • 6.4. Data is downloaded.
  • 6.5. Data is entered for new specifications.
  • 6.6. Successful data entry is verified.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Faults are rectified
Adjustments and replacements which do not include the repair of components
Input components
Sensors, actuators, resistors, capacitors, diodes, transistors, ICs, EPROMs, microprocessors
Output components
Hardware, software, hard copy devices, soft storage devices
Specifications
Manufacturer and/or vendor specifications
Standard operating procedures
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to test, diagnose and maintain electronic controlling systems on mobile plant Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with testing, diagnosing and maintaining electronic controlling systems on mobile plant, or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
Replaces
State Code National Code Title Type
M1484 MEM18.47AA Diagnose and maintain electronic controlling systems on mobile plant Unit of competency
Replaced By
State Code National Code Title Type
OAT22 MEM27016 Diagnose and maintain electronic controlling systems on mobile and stationary plant Unit of competency