Unit of competency Outline

Date retreived
23/07/2026 3:15 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Install sewerage pump sets

Install sewerage pump sets

Unit of competency
National Code
CPCPSN3016A
State Code
D7496
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
19/05/2011
State Implementation and Classification
Approved Date
27/09/2011
Field of Education
040327 - Plumbing
Original Release Date
27/09/2011
Nominal Hours
8
Description
This unit of competency specifies the outcomes required to install sewerage pumps, and install and test small bore macerators.
Notes
Elements and Performance Criteria
1. Prepare for work.
  • 1.1. Drawings and specifications are obtained.
  • 1.2. Safety (OHS) requirements associated with installing sewerage pump sets, and workplace environmental requirements, are adhered to throughout the work.
  • 1.3. Quality assurance requirements are identified and adhered to in accordance with workplace requirements.
  • 1.4. Tasks are planned and sequenced in conjunction with others involved in or affected by the work and statutory and regulatory authority requirements.
  • 1.5. Tools and equipment for installing sewerage pump sets, including personal protective equipment, are selected and checked for serviceability.
  • 1.6. Work area is prepared to support efficient installation of sewerage pump sets.
2. Identify installation requirements.
  • 2.1. Location of pump is determined following site inspection.
  • 2.2. Pump base requirements are determined from drawings and specifications and other relevant information.
  • 2.3. Materials and equipment are identified, ordered and collected in accordance with workplace procedures.
  • 2.4. Materials and equipment are checked for compliance with standards, docket and order form, and for acceptable condition.
3. Install sewerage pump equipment.
  • 3.1. Pump is set out to comply with drawings, specifications, site requirements or job instructions, with consideration to the location of existing services.
  • 3.2. Pumping equipment is installed in specified locations using recommended fixings.
  • 3.3. Pipework and pump controls are connected in accordance with drawings, specifications, manufacturer requirements and standards.
  • 3.4. Fuel tank fitting, alignment of shafts and couplings, and the use of mechanical joints comply with relevant specifications and manufacturer instructions.
  • 3.5. Pumping equipment and related pipework are tested in accordance with standards and manufacturer recommendations, and test data is recorded in required format.
4. Clean up.
  • 4.1. Work area is cleared and materials disposed of or recycled in accordance with state and territory legislation and workplace procedures.
  • 4.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.
  • 4.3. Documentation is completed in accordance with workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
dirt mounds
hazardous materials and substances
other machines
recently filled trenches
surrounding structure and facilities
traffic control
trip hazards
underground services
use of tools and equipment
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Statutory and regulatory authorities include:
state or territory statutory authority
statutory gasfitting authority
statutory plumbing authority.
Tools and equipment may include:
hand and power tools
measuring and alignment tools
tools and equipment, including:
chain blocks
concreting tools
forklifts
hand trolleys
hoists and jacks
lifting and load shifting equipment
rollers.
Sewerage pump sets may include:
compressed air injectors
wet wells, including submersible pumps.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to installing sewerage pump sets
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Materials may include:
sewerage pump sets, motors and fittings.
Pump controls may be:
automatic controls, which may be float, level or flow switches
manual.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to install and test pre-treatment facilities
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, install a small bore macenator from a water closet to an approved point of discharge up to 4 metres away, ensuring:
correct identification of location, design and details of the proposed installations
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
State Code National Code Title Type
W9756 CPCPSN3006A Install sewerage pump sets Unit of competency
Replaced By
State Code National Code Title Type
WF962 CPCPSN3026A Install sewerage pumpsets Unit of competency
No information