Unit of competency Outline
Date retreived
23/07/2026 6:07 PM AWST
23/07/2026 6:07 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Create or modify automated calibration procedures
Create or modify automated calibration procedures
Unit of competency
National Code
MSL905003
MSL905003
State Code
AWO70
AWO70
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
16/08/2016
Field of Education
019909 - Laboratory Technology
Original Release Date
16/08/2016
Nominal Hours
80
Description
This unit of competency covers the ability to create, edit, test and document computer controlled calibration procedures for test and measurement instruments. This may be in response to the introduction of alternative or new equipment, changing test circumstances, activities involved in research and development trials or to meet client needs. The unit covers performance of automated, including computer-aided, calibrations as well as the programming and control of automated calibration systems.This unit of competency is applicable to calibration technicians/specialists who carry out tests and/or calibrations in first, second and third-party laboratories, and laboratories where testing and/or calibration forms part of inspection or product certification. They require a substantial, in-depth technical knowledge across a broad spectrum of advanced calibration practices and technologies, including a thorough understanding of equipment specifications and proprietary software writing skills. They are authorised by their laboratory to create or modify calibration procedures. They work with limited guidance and results of their work are checked by the laboratory manager, quality inspector or designated signatory.While no specific licensing or certification requirements apply to this unit at the time of publication, laboratory operations are governed by relevant legislation, regulations and/or external accreditation requirements. Local requirements should be checked.
Notes
Elements and Performance Criteria
1 Assess the suitability of available automated procedures
- 1.1 Determine the technical and quality deficiencies of the current automated calibration procedure
- 1.2 Research alternative established procedures, if available
- 1.3 Establish whether an available procedure can be customised or if a new procedure is needed
- 1.4 Obtain internal approval to develop an automation plan and strategy
- 1.5 Identify the resources required for automation and verify they meet necessary quality, laboratory and technical requirements
- 1.6 Confirm that the automated procedure will meet the needs of the client, if applicable
2 Create or edit automated procedure
- 2.1 Identify and document all relevant calibration data to be collected, including parameters and ranges to be tested
- 2.2 Check that instructions are adequately documented to ensure repeatability of test
- 2.3 Document hazards and safety measures to be observed
- 2.4 List the requirements for calibration approval and rejection
- 2.5 Specify data to be recorded and produce a results template, if required
- 2.6 Edit or compile the procedure using appropriate software
- 2.7 Confirm that all calibration requirements can be fulfilled by using the procedure
- 2.8 Test run the program, check errors and debug as necessary
3 Configure instruments/equipment
- 3.1 Use the appropriate personal protective equipment (PPE), safety equipment and procedures
- 3.2 Configure workstation, reference standards, instruments and equipment
- 3.3 Verify performance of reference standards, instruments and equipment prior to use and adjust or calibrate as necessary
- 3.4 Identify and minimise potential sources of measurement error
4 Refine the automated procedure
- 4.1 Run automated procedure to confirm functionality of all steps
- 4.2 Recognise non-conforming results or data and amend the program or troubleshoot procedure/equipment as necessary
- 4.3 Verify all data are the result of valid measurements and all calculations are correct
- 4.4 Confirm the integrity of procedure at each step to ensure repeatability of measurement
5 Verify automated procedure is fit for purpose
- 5.1 Generate a calibration report and compare results achieved with other methods
- 5.2 Systematically analyse all measurement and environmental factors that may influence results and take corrective action
- 5.3 Quantify the uncertainties of results by analysing equipment specifications and test methodology
- 5.4 Arrange for internal peer checking of procedure, data and results and incorporate feedback
- 5.5 Review feedback from other laboratories to assess acceptance of procedure, if applicable
- 5.6 Confirm the procedure is fit for purpose and relevant to the client's needs and document as required
6 Document and review automated procedure
- 6.1 Ensure that the procedure is written in accordance with workplace procedures or statutory and regulatory requirements
- 6.2 Ensure that the procedure has been reviewed in accordance with workplace procedures
- 6.3 Report and present the procedure to appropriate personnel for validation before use
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WA658 | MSL905003A | Create or modify automated calibration procedures | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAC75 | MSL905006 | Create or modify automated calibration procedures | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| AZR8 | MSL60116 | Advanced Diploma of Laboratory Operations | Qualification |
| AZS7 | MSL40116 | Certificate IV in Laboratory Techniques | Qualification |
| AZS1 | MSL50116 | Diploma of Laboratory Technology | Qualification |