Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Perform standard calibrations

Perform standard calibrations

Unit of competency
National Code
MSL904001
State Code
AWO72
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
01/03/2016
State Implementation and Classification
Approved Date
16/08/2016
Field of Education
019909 - Laboratory Technology
Original Release Date
16/08/2016
Nominal Hours
60
Description
This unit of competency covers the ability to calibrate test and measurement equipment in accordance with standard calibration procedures and documented test methods. These procedures/methods specify all associated reference standards, materials, equipment and methods to be used and the required parameters or quantities and ranges to be tested, including the criteria for rejection or approval.This unit of competency is applicable to laboratory and calibration technicians who carry out tests and/or calibrations using standard calibration methods in first, second and third party laboratories, and laboratories where testing and/or calibration forms part of inspection or product certification. Personnel are not permitted to deviate from explicit instructions in any manner, modify the procedure, nor substitute alternative equipment. They work under limited supervision and results of their work are interpreted and checked by the laboratory supervisor, quality inspector or designated signatory.While no specific licensing or certification requirements apply to this unit at the time of publication, laboratory operations are governed by relevant legislation, regulations and/or external accreditation requirements. Local requirements should be checked.
Notes
Elements and Performance Criteria
1 Prepare items for calibration
  • 1.1 Select the authorised calibration procedure in accordance with workplace procedures
  • 1.2 Identify hazards and use appropriate personal protective equipment (PPE), safety equipment and procedures
  • 1.3 Confirm all measuring equipment meets the laboratory's specification requirements and complies fully with the calibration procedure
  • 1.4 Assemble and set up specified reference standards and associated equipment prior to testing
  • 1.5 Verify performance of reference standards and measuring equipment prior to use and adjust or calibrate as necessary
  • 1.6 Identify and minimise potential sources of measurement error
2 Perform calibration
  • 2.1 Perform individual tests without variance according to the documented procedure to ensure repeatability of measurement
  • 2.2 Confirm readings are the result of a valid measurement and record data as required (as-found or before adjustment)
  • 2.3 Adjust device under test to bring readings within specification and record data (as-left or after adjustment) where required
  • 2.4 Analyse resulting test data to detect trends or inconsistencies that would significantly affect the accuracy or validity of test results
  • 2.5 Seek appropriate advice when interpretation of results is outside authorised scope of approval
3 Document results
  • 3.1 Estimate and document uncertainty of measurement in accordance with workplace procedures, where required
  • 3.2 Document compliance/non-compliance with test requirements and/or specifications
  • 3.3 Record the results of each test/calibration accurately, unambiguously and objectively
  • 3.4 Ensure confidentiality of workplace information
4 Finalise calibration
  • 4.1 Prepare and issue a final report on the job/item detailing testing carried out, traceability, statement of compliance and relevant information as required
  • 4.2 Report any non-compliance and verify next course of action with supervisor
  • 4.3 Attach calibration labels, equipment stickers, quality control tags and tamper resistant seals as required in workplace procedures
  • 4.4 Store test equipment/measurement standards and results in accordance with workplace procedures
No information
No information
Replaces
State Code National Code Title Type
WA655 MSL904001A Perform standard calibrations Unit of competency
Replaced By
State Code National Code Title Type
OAC22 MSL904002 Perform standard calibrations Unit of competency
State Code National Code Title Type
BCU9 MSS50216 Diploma of Environmental Monitoring and Technology Qualification
BCU6 MSS40216 Certificate IV in Environmental Monitoring and Technology Qualification
AZR8 MSL60116 Advanced Diploma of Laboratory Operations Qualification
AZR9 MSL30116 Certificate III in Laboratory Skills Qualification
AZS1 MSL50116 Diploma of Laboratory Technology Qualification
BDI7 AMP30216 Certificate III in Meat Processing (Food Services) Qualification
BDJ0 AMP30616 Certificate III in Meat Processing (General) Qualification
BDH9 AMP40516 Certificate IV in Meat Processing (Meat Safety) Qualification
BDH8 AMP30316 Certificate III in Meat Processing (Meat Safety) Qualification
BDI6 AMP31216 Certificate III in Meat Processing (Packing Operations) Qualification
BDI2 AMP30716 Certificate III in Meat Processing (Quality Assurance) Qualification
BDJ1 AMP30916 Certificate III in Meat Processing (Smallgoods - General) Qualification
BDI3 AMP31016 Certificate III in Meat Processing (Smallgoods - Manufacture) Qualification
BAH5 PPM20216 Certificate II in Papermaking Operations Qualification
BAH0 PPM40216 Certificate IV in Papermaking Operations Qualification
BAH2 PPM30216 Certificate III in Papermaking Operations Qualification
BAH4 PPM20116 Certificate II in Pulping Operations Qualification
BAH1 PPM30116 Certificate III in Pulping Operations Qualification
BAK2 PPM40116 Certificate IV in Pulping Operations Qualification
BDD6 AHC41516 Certificate IV in Seed Testing Qualification