Unit of competency Outline
Date retreived
22/07/2026 6:19 AM AWST
22/07/2026 6:19 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install lead-in module and cable for fibre to the premises
Install lead-in module and cable for fibre to the premises
Unit of competency
National Code
ICTBWN3090A
ICTBWN3090A
State Code
D3295
D3295
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
26/11/2013
Field of Education
031309 - Communications Equipment Installation And Maintenance
Original Release Date
26/11/2013
Nominal Hours
45
Description
This unit describes the performance outcomes, skills and knowledge required to install a lead-in module and its associated cable for a fibre to the premises (FTTP) installation.Optical networks and FTTP are part of the strategies by service providers using wave division multiplexing (WDM) to deliver very high speed broadband capacity through the Access Network for the National Broadband Network (NBN) initiative.FTTP services can be underground or aerial and may include hybrid fibre coaxial (HFC) installations.Assessment by a TITAB registered assessor is recommended.Licensing, legislative, regulatory and certification requirements apply to working at heights. If an elevated work platform (EWP) is required, verify state or territory law requirements for a licence to operate an EWP. Users should confirm requirements with the relevant federal, state or territory authority.If working at heights, achievement of the unit 'CPCPCM2015A Work safely on roofs' from the CPC08 Construction and Plumbing Services Integrated framework training Package fulfils this requirement.
Notes
Elements and Performance Criteria
1. Set up and prepare for installation
- 1.1. Obtain relevant legislation, codes, regulations and standards for compliance when conducting work
- 1.2. Scope the work by obtaining project plan from appropriate personnel and arrange for site access to comply with security arrangements
- 1.3. Notify appropriate personnel of identified safety hazards at the work site
- 1.4. Determine type of lead-in module and cable from project plan and identify installation requirements using work instructions
- 1.5. Obtain tools and safety equipment and material to perform tasks safely and efficiently
- 1.6. Select and use required protective equipment and make site safe and secure for installation work
- 1.7. Obtain lead-in module and visually inspect for lead-in moduledamage and replace if necessary
2. Install lead-in module in enclosure
- 2.1. Follow occupational health and safety (OHS) and environmental requirements for the given work and identify and avoid other services
- 2.2. Identify position in enclosure to secure module and install mounting bracket according to manufacturer's specifications
- 2.3. Splice lead-in module tail to distribution joint
- 2.4. Attach lead-in module to mounting bracket and secure in position
3. Install optical fibre lead-in cable to premises
- 3.1. Unpack and prepare lead-in cable according to manufacturer's specifications
- 3.2. Haul optical fibre lead-in cable to premises observing maximum strain on cable for underground installation
- 3.3. Coil excess cable length within enclosure
- 3.4. Install aerial lead-in using catenary and bearer wire to meet relevant height and minimum sag requirements
4. Terminate the lead-in cable at the premises
- 4.1. Access the optical network terminating (ONT) unit to expose lead-in cable to retrieve fibre and connector
- 4.2. Clean ONT adapter and connector according to manufacturer's specifications
- 4.3. Mate fibre connector with ONT adapter ensuring free of contaminants
- 4.4. Route fibre cable within ONT and secure in position
- 4.5. Test operation of lead-in at the ONT for optical power levels at the designated operating WDM optical wavelength
- 4.6. Record connections, test results and park unused fibre leads for safety reasons according to organisational policy
5. Clean up work site
- 5.1. Seal ONT and enclosure
- 5.2. Remove installation waste and debris from worksite and dispose of according to environmental requirements
- 5.3. Notify appropriate personnel of job completion and obtain sign off
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Relevant legislation, codes, regulations and standards may include:
appropriate licences:
winch
crane
forklift
EWP
Australian Communications Industry Forum (ACIF) standards and codes
AS Communications Cabling Manual (CCM) Volume 1
AS/NZS 3000:2007
AS/NZS 3080:2003
AS/NZS 3084:2003
AS/NZS 3085.1:2004
AS/NZS IEC 61935.1:2006
AS/NZS IEC 61935.2:2006
AS/NZS ISO/IEC 14763.3:2007
AS/NZS ISO/IEC 15018:2005
AS/NZS ISO/IEC 24702:2007
cabling security codes and regulations
Environmental Protection Acts
OHS
road and traffic control legislation and codes
technical standards AS/ACIF S008:2006 and AS/ACIF S009:2006.
Appropriate personnel may be:
consultant
project engineer
project supervisor
site supervisor.
Safety hazards may refer to:
access points that may contain:
hazardous light (non-visible laser)
radio frequency (RF) emission
active lasers with no safety labels
active optical fibres
contact with remote power feed
electrical supply that require mandatory separation from communications cable
exposed fibres
unsafe support structures
unsafe weather:
heavy rains
high winds
severe heat or cold
thunderstorms.
Lead-in module may include:
1310 nm
1490 nm
1550 nm.
Installation requirements may refer to:
aerial
underground
combination of underground and aerial.
Tools and safety equipment may include:
personal protective equipment
safety equipment
test equipment:
passive optical network (PON) meter
optical time domain reflectometer (OTDR)
local area network (LAN) Cat tester
network analyser
tools:
fibre cleaning kit
fibre splicer
labeller
screw drivers
spanners
tagging tool.
Lead-in moduledamage may include:
cuts in fibre sheathing
end caps on connectors
kinks in fibre leads
physical damage to module body.
OHS and environmental requirements may relate to:
identifying other services, including power and gas
personal protective equipment:
earmuffs
gloves:
leather
plastic
rubber
head protection
masks
protective suits
safety boots
safety glasses
safe working practices, such as the safe use and handling of:
chemicals
materials
tools and equipment
safety equipment:
flashing lights
safety barriers
warning signs and tapes
witches hats
special access requirements
environmental considerations:
clean-up protection
stormwater protection
waste management.
Other services may include:
alarms
electrical services
fire sprinkler systems
gas and water mains
high voltage (HV) power
other service provider networks.
Enclosure may include:
cabinet
FTTP cabinet
HFC housing
housing
pit.
Maximum strain may relate to:
typically 600 nm
verify with manufacturer's for specific value.
Clean ONT adapter and connector may use:
dry clean
lint-free swabs
lint-free wipes
wet clean.
Contaminants may include:
chips
dry residue
dust
liquids
scratches.
WDM Optical wavelength is one of:
1310 nm
1490 nm
1550 nm.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Relevant legislation, codes, regulations and standards may include:
appropriate licences:
winch
crane
forklift
EWP
Australian Communications Industry Forum (ACIF) standards and codes
AS Communications Cabling Manual (CCM) Volume 1
AS/NZS 3000:2007
AS/NZS 3080:2003
AS/NZS 3084:2003
AS/NZS 3085.1:2004
AS/NZS IEC 61935.1:2006
AS/NZS IEC 61935.2:2006
AS/NZS ISO/IEC 14763.3:2007
AS/NZS ISO/IEC 15018:2005
AS/NZS ISO/IEC 24702:2007
cabling security codes and regulations
Environmental Protection Acts
OHS
road and traffic control legislation and codes
technical standards AS/ACIF S008:2006 and AS/ACIF S009:2006.
Appropriate personnel may be:
consultant
project engineer
project supervisor
site supervisor.
Safety hazards may refer to:
access points that may contain:
hazardous light (non-visible laser)
radio frequency (RF) emission
active lasers with no safety labels
active optical fibres
contact with remote power feed
electrical supply that require mandatory separation from communications cable
exposed fibres
unsafe support structures
unsafe weather:
heavy rains
high winds
severe heat or cold
thunderstorms.
Lead-in module may include:
1310 nm
1490 nm
1550 nm.
Installation requirements may refer to:
aerial
underground
combination of underground and aerial.
Tools and safety equipment may include:
personal protective equipment
safety equipment
test equipment:
passive optical network (PON) meter
optical time domain reflectometer (OTDR)
local area network (LAN) Cat tester
network analyser
tools:
fibre cleaning kit
fibre splicer
labeller
screw drivers
spanners
tagging tool.
Lead-in moduledamage may include:
cuts in fibre sheathing
end caps on connectors
kinks in fibre leads
physical damage to module body.
OHS and environmental requirements may relate to:
identifying other services, including power and gas
personal protective equipment:
earmuffs
gloves:
leather
plastic
rubber
head protection
masks
protective suits
safety boots
safety glasses
safe working practices, such as the safe use and handling of:
chemicals
materials
tools and equipment
safety equipment:
flashing lights
safety barriers
warning signs and tapes
witches hats
special access requirements
environmental considerations:
clean-up protection
stormwater protection
waste management.
Other services may include:
alarms
electrical services
fire sprinkler systems
gas and water mains
high voltage (HV) power
other service provider networks.
Enclosure may include:
cabinet
FTTP cabinet
HFC housing
housing
pit.
Maximum strain may relate to:
typically 600 nm
verify with manufacturer's for specific value.
Clean ONT adapter and connector may use:
dry clean
lint-free swabs
lint-free wipes
wet clean.
Contaminants may include:
chips
dry residue
dust
liquids
scratches.
WDM Optical wavelength is one of:
1310 nm
1490 nm
1550 nm.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
use optical power test equipment
measure optical signals at three WDM wavelengths
install lead-in module in the enclosure for both an aerial and underground installation
demonstrate successful completion of the procedures
complete connection recording
comply with all related OHS requirements and work practices.
Context of, and specific resources for assessment
Assessment must ensure:
access to a telecommunications operations site where installation of lead-in module and cable for FTTP may be conducted
a fibre lead-in module, distribution pit, premises conduit and relevant ONT
use of tools, equipment and personal protective equipment currently used in industry
relevant regulatory and equipment documentation that impacts on work activities.
Methods of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
direct observation of the candidate installing lead-in module and cable for FTTP applying all related OHS requirements and work practices
direct observation of the candidate measuring optical signals at three WDM wavelengths
oral or written questioning to assess required knowledge.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplaces and job role is recommended, for example:
ICTBWN3088A Install optical fibre splitters in fibre distribution hubs
ICTBWN3100A Work safely with live fibre to test and commission a fibre to the x installation.
Aboriginal people and other people from a non-English speaking background may have second language issues.
Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.
In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.
Where applicable, physical resources should include equipment modified for people with special needs.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
use optical power test equipment
measure optical signals at three WDM wavelengths
install lead-in module in the enclosure for both an aerial and underground installation
demonstrate successful completion of the procedures
complete connection recording
comply with all related OHS requirements and work practices.
Context of, and specific resources for assessment
Assessment must ensure:
access to a telecommunications operations site where installation of lead-in module and cable for FTTP may be conducted
a fibre lead-in module, distribution pit, premises conduit and relevant ONT
use of tools, equipment and personal protective equipment currently used in industry
relevant regulatory and equipment documentation that impacts on work activities.
Methods of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
direct observation of the candidate installing lead-in module and cable for FTTP applying all related OHS requirements and work practices
direct observation of the candidate measuring optical signals at three WDM wavelengths
oral or written questioning to assess required knowledge.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplaces and job role is recommended, for example:
ICTBWN3088A Install optical fibre splitters in fibre distribution hubs
ICTBWN3100A Work safely with live fibre to test and commission a fibre to the x installation.
Aboriginal people and other people from a non-English speaking background may have second language issues.
Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.
In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.
Where applicable, physical resources should include equipment modified for people with special needs.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| WI866 | ICTBWN3090B | Install lead-in module and cable for fibre to the premises | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| D556 | ICA30111 | Certificate III in Information, Digital Media and Technology | Qualification |