Unit of competency Outline

Date retreived
22/07/2026 1:53 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Prepare a scope of works for remedial waterproofing

Prepare a scope of works for remedial waterproofing

Unit of competency
National Code
CPCCWP5005
State Code
OEM28
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
08/12/2022
State Implementation and Classification
Approved Date
06/04/2023
Field of Education
040313 - Ceiling, Wall And Floor Fixing
Original Release Date
06/04/2023
Nominal Hours
35
Description
This unit of competency specifies the skills and knowledge required to prepare a report for remedial scoping requirements as a result of the diagnosis of cause of water and moisture ingress in construction. The unit applies to Class 1 and 10 Buildings, and Class 2 to 9 Buildings.The unit covers planning and preparing to develop a scope of works, developing the scope and specifications, and documenting the scope of works and specifications. The unit is suitable for builders, building supervisors, building surveyors, building designers, architects, waterproofing design specialists, waterproofing supervisors, and consultants, engineers or other design specialists. Licensing, legislative, regulatory or certification requirements may apply to this unit. Relevant work health and safety (WHS) state and territory regulatory authorities should be consulted to confirm jurisdictional requirements.
Notes
Elements and Performance Criteria
1. Plan and prepare.
  • 1.1 Review design specifications and water ingress report, including drawings, building and structures.
  • 1.2 Confirm stakeholder’s design brief and expectations, including timelines, finishes, systems and warranty.
  • 1.3 Confirm relevant regulatory requirements.
  • 1.4 Liaise with other specialist consultants, including engineers, building surveyors and local councils.
2. Develop scope and specifications.
  • 2.1 Determine extent of the scope of works, including site conditions, demolition, occupant use, safety, specifications and quality assurance.
  • 2.2 Develop waterproofing design in line with design brief.
  • 2.3 Consult with product manufacturers and research appropriate systems in line with design brief.
  • 2.4 Confirm effectiveness of waterproofing design for compliance and suitability with site conditions in accordance with National Construction Code (NCC) performance requirements, Australian Standards and manufacturers’ requirements.
3. Document scope of works and specifications.
  • 3.1 Write scope of works to include establishment of site, roles and responsibilities, safety, stages, statutory requirements and site hand-over.
  • 3.2 Document the system specifications in accordance with manufacturers’ requirements.
  • 3.3 Document hold points and other quality assurance requirements.
  • 3.4 Communicate scope of works and specifications to stakeholders.
No information
No information
No information