Unit of competency Outline
Date retreived
22/07/2026 11:38 PM AWST
22/07/2026 11:38 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Conduct and validate pH/temperature declines to MSA standards
Conduct and validate pH/temperature declines to MSA standards
Unit of competency
National Code
AMPQUA407
AMPQUA407
State Code
OFA76
OFA76
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
21/06/2023
Field of Education
030307 - Food Processing Technology
Original Release Date
21/06/2023
Nominal Hours
20
Description
This unit covers the skills and knowledge required to accurately calibrate and maintain pH equipment, to conduct pH/temperature declines and weekly monitoring, and to validate results to ensure conformance to the pH/temperature window.It is a licence requirement for Meat Standards Australia (MSA) workplaces to achieve the pH/temperature window.The skills and knowledge gained from this unit will allow individuals to monitor pH or temperature window to AUS-MEAT and MSA standards. This unit is suitable for people working in quality assurance or a company grading role.All work must be carried out to comply with workplace procedures, according to state/territory health and safety, food and meat safety regulations, legislation and standards that apply to the workplace.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1. Operate and calibrate pH equipment
- 1.1 Conduct calibrations on temperature measurement equipment
- 1.2 Conduct calibrations on pH monitoring equipment
- 1.3 Demonstrate correct technique for pH/temperature measurement
2. Monitor the pH/temperature window of carcases
- 2.1 Conduct pH/temperature checks for validation purposes, in line with AUS-MEAT standards
- 2.2 Collect weekly and monthly data to ensure compliance with the pH/temperature window
- 2.3 Ensure readings are valid and sufficient
- 2.4 Record and report results
3. Analyse monitoring data
- 3.1 Generate reports for analysis of pH/temperature monitoring
- 3.2 Analyse results of pH/temperature monitoring
- 3.3 Recognise effects of heat shortening and cold shortening
- 3.4 Identify pH/temperature window
4. Suggest corrective action plans for non-conformance
- 4.1 Identify and evaluate factors impacting on pH/temperature window conformance
- 4.2 Identify reasons for non-conformance
- 4.3 Suggest corrective actions for window non-conformance
- 4.4 Conduct trials to achieve window conformance
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| AVX18 | AMPA404 | Conduct and validate pH and temperature declines to MSA standards | Unit of competency |
| BAY50 | AMPA3118 | Monitor pH and temperature decline | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BIZ4 | AMP40222 | Certificate IV in Meat Processing | Qualification |