Unit of competency Outline
Date retreived
22/07/2026 5:41 AM AWST
22/07/2026 5:41 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Modify instrumentation equipment
Modify instrumentation equipment
Unit of competency
National Code
UTPNEG252A
UTPNEG252A
State Code
M1683
M1683
TGA Status
Replaced
Replaced
DTWD Status
Archived
Archived
State Implementation and Classification
Approved Date
Field of Education
031317 - Electronic Equipment Servicing
Original Release Date
Nominal Hours
50
Description
Notes
Elements and Performance Criteria
No information
Stream: Production Plant
Field: Maintenance
Equivalencies: This unit of competence is based on unit 6.3 of the Electrical Contractors
Industry Association Competency Standards (Instrumentation Stream)
Inspection should be planned with the appropriate parties to determine access, conditions and work requirements
Equipment may include gauges, transmitters, switches, thermocouples, RTDs, thermostats, indicators, meters, proximity probes, indication slide wires, control valves, valve positioners, lock up valves, power cylinders, power cylinder positioners, I/P and E/P converters, air relays, pressure regulators, solenoid valves, analogue indicators, fire detectors, smoke detectors, vibration detectors, gas detectors and fuel valve
Materials may include fixings such as bolts, nuts, screws, masonry anchors, cable and tube anchors, flexible multicore cable, brackets, cleaning solvents, lugs such as solder, non-insulated crimp and pre-insulated crimp, connectors such as wire termination devices, co-axial, multi-pin plug and socket, tag strips, pins and spades, tube termination devices, tube-tube connectors and bulkhead-tube, soft solder and flumes, lubricants, cleaning solvents, gasket materials, leak test solution, connectors and fittings
Components may include hair springs, gauge movements, pneumatic restrictors, air relays, microswitches, flapper/nozzles, diaphragms, springs, bellows, gaskets, shuttle valves, pilot valves, amplifier modules, coils and plug in printed circuit boards
Test and measurement instruments may include dead weight tester, pneumatic calibrator, vacuum pump gauge/, manometer, precision pressure gauge, hand-held pressure pump, comparator, temperature baths, oven, multimeter, variable power supply, DC I/V standard, potentiometer and decade box
Work completion details may include plant and maintenance records, job cards, check sheets and on device labelling updates
Work site environment may be affected by nearby plant or processes, e.g. heat, noise, dust, oil, water and chemical
Isolations can refer to electrical/mechanical or other associated processes
Field: Maintenance
Equivalencies: This unit of competence is based on unit 6.3 of the Electrical Contractors
Industry Association Competency Standards (Instrumentation Stream)
Inspection should be planned with the appropriate parties to determine access, conditions and work requirements
Equipment may include gauges, transmitters, switches, thermocouples, RTDs, thermostats, indicators, meters, proximity probes, indication slide wires, control valves, valve positioners, lock up valves, power cylinders, power cylinder positioners, I/P and E/P converters, air relays, pressure regulators, solenoid valves, analogue indicators, fire detectors, smoke detectors, vibration detectors, gas detectors and fuel valve
Materials may include fixings such as bolts, nuts, screws, masonry anchors, cable and tube anchors, flexible multicore cable, brackets, cleaning solvents, lugs such as solder, non-insulated crimp and pre-insulated crimp, connectors such as wire termination devices, co-axial, multi-pin plug and socket, tag strips, pins and spades, tube termination devices, tube-tube connectors and bulkhead-tube, soft solder and flumes, lubricants, cleaning solvents, gasket materials, leak test solution, connectors and fittings
Components may include hair springs, gauge movements, pneumatic restrictors, air relays, microswitches, flapper/nozzles, diaphragms, springs, bellows, gaskets, shuttle valves, pilot valves, amplifier modules, coils and plug in printed circuit boards
Test and measurement instruments may include dead weight tester, pneumatic calibrator, vacuum pump gauge/, manometer, precision pressure gauge, hand-held pressure pump, comparator, temperature baths, oven, multimeter, variable power supply, DC I/V standard, potentiometer and decade box
Work completion details may include plant and maintenance records, job cards, check sheets and on device labelling updates
Work site environment may be affected by nearby plant or processes, e.g. heat, noise, dust, oil, water and chemical
Isolations can refer to electrical/mechanical or other associated processes
Critical aspects of evidence
The knowledge and application of relevant sections of: Occupational, health and safety legislation; Statutory legislation; Enterprise/site safety procedures; Enterprise/site emergency procedures
Attainment of electrical licence, where appropriate, deeming competency associated with electrical work
Preparation and planning of work
Modification techniques and procedures
Completion of work procedures
Context of assessment
Competency Standards should be assessed in the workplace or simulated workplace and under the normal range of workplace conditions
Assessment of this unit will be supported with documentary evidence, by means of endorsement stating type and work
Interdependent assessment of unit
Nil
Knowledge and Skills
A knowledge of:
Occupational health and safety standards; Relevant statutory requirements and codes of practice; Relevant Australian standards; Equipment and material required to perform the work; Isolation procedures; General layout of plant/work site and operation of its equipment; Modification techniques; Instrumentation equipment and technology; Regulatory aspects; Electrical fundamentals; Test and measurement instruments; Engineering and workshop practice; Communication principles
The ability to:
Apply occupational health and safety standards; Follow relevant statutory regulations and codes of practice; Apply relevant Australian standards; Locate and interpret plans, drawings and text; Modify instrumentation equipment; Update plans, drawings and text; Use tools and relevant equipment; Use test and measurement instruments; Identify and select materials for the job; Apply regulatory aspects theory; Apply electrical fundamentals theory; Carry out work completion details; Communicate effectively; Apply data analysis techniques and tools.
The knowledge and application of relevant sections of: Occupational, health and safety legislation; Statutory legislation; Enterprise/site safety procedures; Enterprise/site emergency procedures
Attainment of electrical licence, where appropriate, deeming competency associated with electrical work
Preparation and planning of work
Modification techniques and procedures
Completion of work procedures
Context of assessment
Competency Standards should be assessed in the workplace or simulated workplace and under the normal range of workplace conditions
Assessment of this unit will be supported with documentary evidence, by means of endorsement stating type and work
Interdependent assessment of unit
Nil
Knowledge and Skills
A knowledge of:
Occupational health and safety standards; Relevant statutory requirements and codes of practice; Relevant Australian standards; Equipment and material required to perform the work; Isolation procedures; General layout of plant/work site and operation of its equipment; Modification techniques; Instrumentation equipment and technology; Regulatory aspects; Electrical fundamentals; Test and measurement instruments; Engineering and workshop practice; Communication principles
The ability to:
Apply occupational health and safety standards; Follow relevant statutory regulations and codes of practice; Apply relevant Australian standards; Locate and interpret plans, drawings and text; Modify instrumentation equipment; Update plans, drawings and text; Use tools and relevant equipment; Use test and measurement instruments; Identify and select materials for the job; Apply regulatory aspects theory; Apply electrical fundamentals theory; Carry out work completion details; Communicate effectively; Apply data analysis techniques and tools.
No information
| State Code | National Code | Title | Type |
|---|---|---|---|
| M084 | UTP30198 | Certificate III in ESI Generation (Electrical/Electronic) | Qualification |