Unit of competency Outline
Date retreived
23/07/2026 12:26 AM AWST
23/07/2026 12:26 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Monitor, operate and control incineration processes
Monitor, operate and control incineration processes
Unit of competency
National Code
NWP349B
NWP349B
State Code
D1925
D1925
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
14/01/2009
Field of Education
030717 - Plant And Machine Operations
Original Release Date
14/01/2009
Nominal Hours
20
Description
This unit of competency describes the outcomes required to monitor, operate and control incineration plant and to measure and report on system performance and process quality control. The ability to identify faults, determine and apply technical adjustments and produce technical reports are essential to performance.
Notes
Elements and Performance Criteria
1Monitor incineration plant performance.
- 1.1 Monitor test results and combustion processes to meet organisational procedures and statutory requirements.
- 1.2 Identify and report process faults and the operational condition of plant according to organisational and statutory requirements.
- 1.3 Select and check equipment and correctly fit and use personal protective equipment.
2Operate and control processes.
- 2.1 Carry out routine plant inspections according to organisational and plant requirements.
- 2.2 Conduct and analyse process tests and compare performance to operational requirements.
- 2.3 Make system adjustments to improve system performance according to organisational and statutory requirements.
- 2.4 Collect, interpret and record process data and report according to organisational and plant requirements.
3Compile process records.
- 3.1 Compile reports from plant and system data to meet organisational procedures and statutory requirements.
- 3.2 Report observations outside defined parameters for further action.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the Performance Criteria, is detailed below. Add any essential operating conditions that may be present with training and assessment depending on the work situation, needs if the candidate, accessibility of the item, and local industry and regional contexts.
Plant may include:
furnace feed conveyors
furnace equipment
combustion fans and equipment
auxiliary fuel system
ash transfer system
ash disposal system
furnace exhaust gas scrubbers
Organisational and statutory requirements may include:
by-laws and organisational policies
standard operating procedures
environment protection
occupational health and safety
Australian Drinking Water Guidelines
National Water Quality Management strategy
chemicals
dangerous goods
lifts and cranes
Environment Protection Authority regulations
licensing agreements
electrical
Inspection may include:
inspection of:
fluidised furnaces
co-fired furnaces
fixed bed furnaces
use of equipment, including:
electronic monitoring and metering systems
manual chart recording systems
basic hand tools
sampling and laboratory testing equipment
computerised equipment
communication equipment
personal protective equipment
interaction and communication with other employees, other authorities and the general public
visual observation
implementation of reporting procedures that may also include procedures for the implementation of by-laws, organisational policies and statutory requirements
Tests may include:
water content
flame temperature
fuel to air ratios
System adjustments may include:
loading rates
centrifuge settings
burner operation
feed rate adjustments
air ratio
Reports may include:
plant performance data
environmental reports
centrifuge performance data
chemical usage
Plant may include:
furnace feed conveyors
furnace equipment
combustion fans and equipment
auxiliary fuel system
ash transfer system
ash disposal system
furnace exhaust gas scrubbers
Organisational and statutory requirements may include:
by-laws and organisational policies
standard operating procedures
environment protection
occupational health and safety
Australian Drinking Water Guidelines
National Water Quality Management strategy
chemicals
dangerous goods
lifts and cranes
Environment Protection Authority regulations
licensing agreements
electrical
Inspection may include:
inspection of:
fluidised furnaces
co-fired furnaces
fixed bed furnaces
use of equipment, including:
electronic monitoring and metering systems
manual chart recording systems
basic hand tools
sampling and laboratory testing equipment
computerised equipment
communication equipment
personal protective equipment
interaction and communication with other employees, other authorities and the general public
visual observation
implementation of reporting procedures that may also include procedures for the implementation of by-laws, organisational policies and statutory requirements
Tests may include:
water content
flame temperature
fuel to air ratios
System adjustments may include:
loading rates
centrifuge settings
burner operation
feed rate adjustments
air ratio
Reports may include:
plant performance data
environmental reports
centrifuge performance data
chemical usage
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The candidate should demonstrate the ability to monitor, operate and control incineration processes, including:
conducting routine plant inspections
taking samples and performing basic tests
preparing and applying incineration processes according to instructions
identifying and reporting system faults
making basic system adjustments according to instructions
completing required documentation
Context of and specific resources for assessment
Access to the workplace and resources including:
documentation that should normally be available in a water industry organisation
relevant codes, standards, and government regulations
Where applicable, physical resources should include equipment modified for people with disabilities.
Access must be provided to appropriate learning and/or assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the language and literacy capacity of the candidate and the work being performed.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice
a decision of competence only taken at the point when the assessor has complete confidence in the person's competence over time and in various contexts
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence
where assessment is for the purpose of recognition (RCC/RPL), the evidence provided will need to be authenticated and show that it represents competency demonstrated over a period of time
assessment can be through simulated project-based activity and must include evidence relating to each of the elements in this unit
In all cases where practical assessment is used it will be combined with targeted questioning to assess the underpinning knowledge. Questioning will be undertaken in a manner appropriate to the skill levels of the operator, any cultural issues that may affect responses to the questions, and reflecting the requirements of the competency and the work being performed.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The candidate should demonstrate the ability to monitor, operate and control incineration processes, including:
conducting routine plant inspections
taking samples and performing basic tests
preparing and applying incineration processes according to instructions
identifying and reporting system faults
making basic system adjustments according to instructions
completing required documentation
Context of and specific resources for assessment
Access to the workplace and resources including:
documentation that should normally be available in a water industry organisation
relevant codes, standards, and government regulations
Where applicable, physical resources should include equipment modified for people with disabilities.
Access must be provided to appropriate learning and/or assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the language and literacy capacity of the candidate and the work being performed.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice
a decision of competence only taken at the point when the assessor has complete confidence in the person's competence over time and in various contexts
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence
where assessment is for the purpose of recognition (RCC/RPL), the evidence provided will need to be authenticated and show that it represents competency demonstrated over a period of time
assessment can be through simulated project-based activity and must include evidence relating to each of the elements in this unit
In all cases where practical assessment is used it will be combined with targeted questioning to assess the underpinning knowledge. Questioning will be undertaken in a manner appropriate to the skill levels of the operator, any cultural issues that may affect responses to the questions, and reflecting the requirements of the competency and the work being performed.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| M1926 | NWP349A | Monitor, operate and control incineration processes | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AVX89 | NWPTRT094 | Operate and control incineration processes | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| D245 | NWP30107 | Certificate III in Water Operations | Qualification |