Unit of competency Outline
Date retreived
22/07/2026 11:33 PM AWST
22/07/2026 11:33 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install air conditioning systems
Install air conditioning systems
Unit of competency
National Code
AURETU2001
AURETU2001
State Code
WF125
WF125
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
18/07/2013
Field of Education
030503 - Vehicle Mechanics
Original Release Date
18/07/2013
Nominal Hours
20
Description
This unit covers the competence required to install air conditioning systems.Licensing, legislative, regulatory or certification requirements may apply to this unit in some jurisdictions. Users are advised to check with the relevant regulatory authority.
Notes
Elements and Performance Criteria
1. Prepare to install air conditioning systems
- 1.1. Nature and scope of work requirements are identified and confirmed
- 1.2. WHS requirements, including individual State/Territory regulatory/licensing requirements and personal protection needs are observed throughout the work
- 1.3. Procedures and information such as schematic diagrams, manufacturer/component supplier instructions, workshop manuals and specifications, and tooling required, are sourced
- 1.4. Method options are analysed and those most appropriate to the circumstances are selected and prepared
- 1.5. Technical and/or calibration requirements for air conditioning components are sourced and support equipment is identified and prepared
- 1.6. Warnings in relation to working with air conditioning and refrigerants are observed
2. Install air conditioning systems
- 2.1. Correct information is accessed and interpreted from manufacturer/component supplier specifications
- 2.2. Fittings/materials are selected
- 2.3. Air conditioning systems are installed using tooling and techniques
- 2.4. Air conditioning system installation is completed without causing damage to any component or system
- 2.5. Installation is tested prior to placing in service and results are documented in accordance with enterprise policies and procedures
- 2.6. Installation is carried out according to industry regulations/ guidelines, WHS legislation, legislation and enterprise procedures/policies
3. Charge air conditioning system with refrigerant and lubricating oil
- 3.1. Correct information is accessed and interpreted from manufacturer/component supplier specifications, industry codes of practice and legislation
- 3.2. Charging of the air conditioning system is completed without causing damage to any component or system
- 3.3. System is performance tested using approved methods and equipment
- 3.4. Charging of the system is carried out according to manufacturer/component supplier specifications, industry regulations/guidelines, WHS legislation, legislation and enterprise policies/procedures
4. Vehicle/equipment is prepared for deliver to customer
- 4.1. Installation schedule documentation is completed
- 4.2. Final inspection is made to ensure protective guards, safety features and cowlings are in place
- 4.3. Final inspection is made to ensure the system is functional, without leaks and work is to workplace expectations
- 4.4. Vehicle/equipment is cleaned to workplace expectations
- 4.5. Job card is processed in accordance with workplace procedures
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Work requirements
Work involved includes installation of air conditioning systems fitted to light vehicles, plant and equipment, heavy vehicles or marine craft (low voltage):
refrigerant leak detecting
refrigerant gassing
component and system testing
performance testing
post-installation adjustments and checks
WHS
WHS requirements are to be in accordance with legislation/regulations/codes of practice and enterprise safety policies and procedures. This may include protective clothing and equipment, use of tooling and equipment, workplace environment and safety, handling of material, use of fire fighting equipment, enterprise first aid, hazard control and hazardous materials and substances
Personal protective equipment
Personal protective equipment is to include that prescribed under legislation/regulations/codes of practice and workplace policies and practices
Safe operating procedures
Safe operating procedures are to include, but are not limited to the conduct of operational risk assessment and treatments associated with vehicular movement, toxic substances, electrical safety, machinery movement and operation, manual and mechanical lifting and shifting, working in proximity to others and site visitors
Emergency procedures
Emergency procedures related to this unit are to include, but are not limited to emergency shutdown and stopping of equipment, extinguishing fires, enterprise first aid requirements and site evacuation
Environmental requirements
Environmental requirements are to include but are not limited to waste management, noise, dust and clean-up management
Quality requirements
Quality requirements are to include, but are not limited to regulations, including Australian Standards, internal company quality policy and standards and enterprise operations and procedures
Statutory/regulatory authorities
Statutory/regulatory authorities may include Federal, State/Territory and local authorities administering acts, regulations and codes of practice
Tooling and equipment
Tooling and equipment may include hand tooling, refrigerant leak detecting equipment, refrigerant recovery and/or recycling equipment, thermometers, ram-air fan, refrigerant re-gassing equipment and air conditioning system kits
Materials
Materials may include spare parts, refrigerant, refrigerant oils and cleaning materials
Communications
Communications are to include, but are not limited to verbal and visual instructions and fault reporting and may include site specific instructions, written instructions, plans or instructions related to job/task, telephones and pagers
Information/documents
Sources of information/documents may include:
verbal or written and graphical instructions, signage, work schedules/plans/specifications, work bulletins, memos, material safety data sheets, diagrams or sketches
safe work procedures related to the installation of air conditioning systems
regulatory/legislative requirements pertaining to the automotive industry, including Australian Design Rules
engineer's design specifications and instructions
organisation work specifications and requirements
instructions issued by authorised enterprise or external persons
Australian Standards
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Work requirements
Work involved includes installation of air conditioning systems fitted to light vehicles, plant and equipment, heavy vehicles or marine craft (low voltage):
refrigerant leak detecting
refrigerant gassing
component and system testing
performance testing
post-installation adjustments and checks
WHS
WHS requirements are to be in accordance with legislation/regulations/codes of practice and enterprise safety policies and procedures. This may include protective clothing and equipment, use of tooling and equipment, workplace environment and safety, handling of material, use of fire fighting equipment, enterprise first aid, hazard control and hazardous materials and substances
Personal protective equipment
Personal protective equipment is to include that prescribed under legislation/regulations/codes of practice and workplace policies and practices
Safe operating procedures
Safe operating procedures are to include, but are not limited to the conduct of operational risk assessment and treatments associated with vehicular movement, toxic substances, electrical safety, machinery movement and operation, manual and mechanical lifting and shifting, working in proximity to others and site visitors
Emergency procedures
Emergency procedures related to this unit are to include, but are not limited to emergency shutdown and stopping of equipment, extinguishing fires, enterprise first aid requirements and site evacuation
Environmental requirements
Environmental requirements are to include but are not limited to waste management, noise, dust and clean-up management
Quality requirements
Quality requirements are to include, but are not limited to regulations, including Australian Standards, internal company quality policy and standards and enterprise operations and procedures
Statutory/regulatory authorities
Statutory/regulatory authorities may include Federal, State/Territory and local authorities administering acts, regulations and codes of practice
Tooling and equipment
Tooling and equipment may include hand tooling, refrigerant leak detecting equipment, refrigerant recovery and/or recycling equipment, thermometers, ram-air fan, refrigerant re-gassing equipment and air conditioning system kits
Materials
Materials may include spare parts, refrigerant, refrigerant oils and cleaning materials
Communications
Communications are to include, but are not limited to verbal and visual instructions and fault reporting and may include site specific instructions, written instructions, plans or instructions related to job/task, telephones and pagers
Information/documents
Sources of information/documents may include:
verbal or written and graphical instructions, signage, work schedules/plans/specifications, work bulletins, memos, material safety data sheets, diagrams or sketches
safe work procedures related to the installation of air conditioning systems
regulatory/legislative requirements pertaining to the automotive industry, including Australian Design Rules
engineer's design specifications and instructions
organisation work specifications and requirements
instructions issued by authorised enterprise or external persons
Australian Standards
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
It is essential that competence in this unit signifies ability to transfer competence to changing circumstances and to respond to unusual circumstances in the critical aspects of:
observing safety procedures and requirements
communicating effectively with others involved in or affected by the work
selecting methods and techniques appropriate to the circumstances
completing preparatory activity in a systematic manner
conducting installation in accordance with the workplace and manufacturer/component supplier requirements
completing leak test and performing tests on the system
accurately interpreting test results
completing installation within workplace timeframes
vehicle/equipment is presented to customer in compliance with workplace requirements
Context of, and specific resources for assessment
Application of competence is to be assessed in the workplace or simulated worksite
Assessment is to occur using standard and authorised work practices, safety requirements and environmental constraints
Assessment is to comply with regulatory requirements, including Australian Standards
The following resources should be made available:
workplace location or simulated workplace
material relevant to the installation of air conditioning systems
equipment, hand and power tooling appropriate to the installation of air conditioning systems
activities covering mandatory task requirements
specifications and work instructions
Method of assessment
Assessment must satisfy the endorsed assessment guidelines of the automotive industry's RS&R Training Package
Assessment methods must confirm consistency and accuracy of performance together with application of underpinning knowledge
Assessment must be by direct observation of tasks, with questioning on underpinning knowledge and it must also reinforce the integration of key competencies
Assessment may be applied under project related conditions and require evidence of process
Assessment must confirm a reasonable inference that competence is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances
It is preferable that assessment reflects a process rather than an event and occurs over a period of time to cover varying quality circumstances. Evidence of performance may be provided by customers, team leaders/members or other persons subject to agreed authentication arrangements
Competence in this unit may be assessed in conjunction with other functional units which together form part of the holistic work role
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
It is essential that competence in this unit signifies ability to transfer competence to changing circumstances and to respond to unusual circumstances in the critical aspects of:
observing safety procedures and requirements
communicating effectively with others involved in or affected by the work
selecting methods and techniques appropriate to the circumstances
completing preparatory activity in a systematic manner
conducting installation in accordance with the workplace and manufacturer/component supplier requirements
completing leak test and performing tests on the system
accurately interpreting test results
completing installation within workplace timeframes
vehicle/equipment is presented to customer in compliance with workplace requirements
Context of, and specific resources for assessment
Application of competence is to be assessed in the workplace or simulated worksite
Assessment is to occur using standard and authorised work practices, safety requirements and environmental constraints
Assessment is to comply with regulatory requirements, including Australian Standards
The following resources should be made available:
workplace location or simulated workplace
material relevant to the installation of air conditioning systems
equipment, hand and power tooling appropriate to the installation of air conditioning systems
activities covering mandatory task requirements
specifications and work instructions
Method of assessment
Assessment must satisfy the endorsed assessment guidelines of the automotive industry's RS&R Training Package
Assessment methods must confirm consistency and accuracy of performance together with application of underpinning knowledge
Assessment must be by direct observation of tasks, with questioning on underpinning knowledge and it must also reinforce the integration of key competencies
Assessment may be applied under project related conditions and require evidence of process
Assessment must confirm a reasonable inference that competence is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances
It is preferable that assessment reflects a process rather than an event and occurs over a period of time to cover varying quality circumstances. Evidence of performance may be provided by customers, team leaders/members or other persons subject to agreed authentication arrangements
Competence in this unit may be assessed in conjunction with other functional units which together form part of the holistic work role
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W5016 | AURT222631A | Install air conditioning systems | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AXD59 | AURETU001 | Install air conditioning systems | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J371 | AUR20212 | Certificate II in Automotive Air Conditioning Technology | Qualification |
| J391 | AUR30312 | Certificate III in Automotive Electrical Technology | Qualification |
| J373 | AUR20412 | Certificate II in Automotive Electrical Technology | Qualification |