Unit of competency Outline

Date retreived
24/07/2026 6:39 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Dive using closed-circuit breathing apparatus (HeO2) in open water to a maximum depth of 60 metres

Dive using closed-circuit breathing apparatus (HeO2) in open water to a maximum depth of 60 metres

Unit of competency
National Code
DEFWDV007
State Code
BBC16
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
17/08/2017
State Implementation and Classification
Approved Date
21/02/2018
Field of Education
031799 - Maritime Engineering And Technology, N.e.c.
Original Release Date
21/02/2018
Nominal Hours
0
Description
This unit specifies the skills and knowledge required to dive using closed circuit breathing apparatus (CCBA) (HeO2) in an open water environment to a maximum depth of 60 metres.It includes operating the HeO2 compressor/handbooster pump, inspecting and operating CCBA (HeO2) equipment, and conducting CCBA (HeO2) specific contingency drills.This unit applies to persons working as Defence Divers but could also apply to others working as work divers.The skills and knowledge described in this unit must be applied within the legislative, regulatory and policy environment in which they are carried out. Organisational policies and procedures must be consulted and adhered to.Persons undertaking this unit work independently and perform specific tasks in a range of contexts that could be unpredictable.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Operate an HeO2 compressor/hand-booster pump
  • 1.1 Inspect compressor and associated equipment for serviceability and report faults in accordance with operational procedures
  • 1.2 Fit appropriate protective equipment in accordance with organisational procedures
  • 1.3 Connect leads and hoses to compressor in accordance with manufacturer instructions
  • 1.4 Charge gas cylinders to maximum working pressure and record details in relevant logs in accordance with organisational procedures
  • 1.5 Conduct operator level maintenance on compressor and report faults, as required in accordance with organisational procedures
  • 1.6 Undertake activity to de-service compressor after use in accordance with operational requirements
2 Conduct dive operations
  • 2.1 Select, inspect and fit CCBA (HeO2), and conduct apparatus test as part of dive preparations prior to entering water and in water, in accordance with dive plan
  • 2.2 Undertake dive activities using CCBA (HeO2) and demonstrate relevant dive contingencies in accordance with organisational procedures and dive plan
  • 2.3 Undertake activity to de-service CCBA (HeO2) and report defects in accordance with operational procedures
  • 2.4 Maintain situational awareness of other divers during dive operations
  • 2.5 Conduct a mid-water casualty handover between an HeO2 standby diver and an air standby diver, in accordance with dive plan
No information
No information
No information