Unit of competency Outline
Date retreived
23/07/2026 4:47 PM AWST
23/07/2026 4:47 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Evaluate and report on building services energy management systems
Evaluate and report on building services energy management systems
Unit of competency
National Code
UEERA0039
UEERA0039
State Code
OBY07
OBY07
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
040305 - Building Surveying
Original Release Date
12/07/2021
Nominal Hours
72
Description
This unit involves the skills and knowledge required to evaluate and report on building services energy management systems, plant and machinery.It includes working safely, setting up and conducting evaluation measurements, evaluating energy use from measured parameters, and reporting results, including recommending any resulting corrective actions.The skills and knowledge described in this unit require a licence or permit to practice in the workplace where work is carried out on electrical installations which are designed to operate at voltages greater than 50 volt (V) alternating current (a.c.) or 120 V direct current (d.c).Competency development activities in this unit are subject to regulations directly related to licensing. Where a licence or permit to practice is not held, skills and knowledge described in this unit require a relevant contract of training, such as an Australian Apprenticeship.Additional and/or other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.Permits may also be required for some work environments, such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation.
Notes
Elements and Performance Criteria
1 Prepare to evaluate and report on energy management
- 1.1 WHS/OHS procedures are obtained and implemented in accordance with workplace procedures
- 1.2 WHS/OHS risk control measures and procedures for work are followed
- 1.3 The extent of evaluation is determined from building services, plant and machinery specifications and discussed with relevant person/s
- 1.4 Advice is sought from work supervisor to ensure work is coordinated effectively with others
- 1.5 Tools, testing devices and materials required for the work are obtained and checked for correct operation and safety in accordance with workplace procedures
2 Evaluate energy management
- 2.1 WHS/OHS risk control measures and workplace procedures for carrying out the work are followed
- 2.2 Need to test or measure live work is determined in accordance with workplace procedures and WHS/OHS requirements
- 2.3 Energy management of building services, plant and machinery is applied to the evaluation process
- 2.4 Energy evaluation tests for each parameter under scrutiny are conducted in accordance with workplace procedures and test methods
- 2.5 Energy evaluation tests are conducted methodically and results/comments systematically noted
- 2.6 Unplanned situations are dealt with safely with the approval of authorised person/s
- 2.7 Evaluation is conducted without damage to systems, circuits, the surrounding environment and/or services using sustainable energy practices
3 Report on energy management
- 3.1 WHS/OHS work completion risk control measures and procedures are followed
- 3.2 Worksite is cleaned and made safe in accordance with workplace procedures
- 3.3 Results of energy management evaluation, including recommendations and justification for improvements, are documented
- 3.4 Energy evaluation report is forwarded to appropriate person/s in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| S7371 | UEENEEJ136A | Evaluate and report on building services energy management systems | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BFQ1 | UEE62520 | Advanced Diploma of Air Conditioning and Refrigeration Engineering | Qualification |
| BFK7 | UEE51220 | Diploma of Air Conditioning and Refrigeration Engineering | Qualification |
| BMB0 | UEE51225 | Diploma of Air Conditioning and Refrigeration Engineering | Qualification |
| BMB1 | UEE62525 | Advanced Diploma of Air Conditioning and Refrigeration Engineering | Qualification |
| BMB9 | UEE42825 | Certificate IV in Air-conditioning Systems Energy Management and Control | Qualification |
| BFL0 | UEE42820 | Certificate IV in Air-conditioning Systems Energy Management and Control | Qualification |
| BFO9 | UEE62420 | Advanced Diploma of Engineering Technology - Air Conditioning and Refrigeration | Qualification |
| BFP3 | UEE51120 | Diploma of Engineering Technology - Refrigeration and Air Conditioning | Qualification |