Unit of competency Outline
Date retreived
23/07/2026 2:32 AM AWST
23/07/2026 2:32 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Connect/disconnect fluid conveying system components
Connect/disconnect fluid conveying system components
Unit of competency
National Code
MEM18071B
MEM18071B
State Code
W5618
W5618
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
18/06/2009
Field of Education
030701 - Mechanical Engineering
Original Release Date
18/06/2009
Nominal Hours
18
Description
This unit covers safely removing/replacing a range of fluid conveying components and assemblies, and inspecting/testing fluid conveying assemblies.
Notes
Elements and Performance Criteria
1. Disconnect fluid conveying components and assemblies
- 1.1. Safety/risk assessment is carried out, potentially hazardous situations/conditions are identified and safety devices are positioned as required.
- 1.2. Fluid conveying conductor lay out is noted, recorded and labelled to standard operating procedures.
- 1.3. Faulty component/assembly is identified using specific trouble-shooting procedures, reference documents and fluid power principles.
- 1.4. Fluid conveying components and assemblies are disconnected and removed using appropriate techniques, procedures, tools and equipment.
- 1.5. Open system is adequately sealed with standard or special purpose sealing materials.
2. Obtain replacement parts
- 2.1. Replacement parts are selected from manufacturer catalogues and other relevant reference sources according to international standards and specifications.
3. Test and store components
- 3.1. Fluid conveying assemblies and individual components are pressure tested according to industry and manufacturer standards and using fluid power principles.
- 3.2. Condition is assessed and noted according to standard operating procedures.
- 3.3. Components/assemblies are cleaned, sealed and stored according to industry and manufacturer standards.
4. Connect fluid conveying components and assemblies
- 4.1. Connections are checked and prepared for reconnection.
- 4.2. Components and assemblies are connected to equipment to specifications using appropriate techniques.
- 4.3. Tagged out equipment, signage and safety blocking devices are removed according to standard operating procedures.
- 4.4. Equipment and fluid conveying systems are checked and tested for correct operation according to manufacturer and industry standards.
5. Report results
- 5.1. Reporting and certification procedures are followed.
- 5.2. All relevant information is completed and correct.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Potentially hazardous situations/conditions
Accumulated pressure, contamination, fluid handling
Reference documents
Manufacturer product catalogues, tables and charts, schematic diagrams
Components and assemblies
High pressure seals, seats, hoses, tubes, pipes, fittings, connectors, adaptors and anchors, and other associated attachments
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Potentially hazardous situations/conditions
Accumulated pressure, contamination, fluid handling
Reference documents
Manufacturer product catalogues, tables and charts, schematic diagrams
Components and assemblies
High pressure seals, seats, hoses, tubes, pipes, fittings, connectors, adaptors and anchors, and other associated attachments
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to connect/disconnect fluid conveying system components. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with connecting/disconnecting fluid conveying system components or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to connect/disconnect fluid conveying system components. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with connecting/disconnecting fluid conveying system components or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| M1793 | MEM18.71AA | Connect/disconnect fluid conveying system components | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAU48 | MEM18071 | Connect and disconnect fluid conveying system components | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| W245 | MEM40105 | Certificate IV in Engineering | Qualification |
| W233 | MEM20105 | Certificate II in Engineering | Qualification |
| W247 | MEM50105 | Diploma of Engineering - Advanced Trade | Qualification |
| W237 | MEM30205 | Certificate III in Engineering - Mechanical Trade | Qualification |
| W236 | MEM30105 | Certificate III in Engineering - Production Systems | Qualification |
| W234 | MEM20205 | Certificate II in Engineering - Production Technology | Qualification |
| W726 | LMT31909 | Certificate III in Engineering - TCF Mechanic | Qualification |