Unit of competency Outline
Date retreived
24/07/2026 1:07 AM AWST
24/07/2026 1:07 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Erect structures
Erect structures
Unit of competency
National Code
MEM10001C
MEM10001C
State Code
W5456
W5456
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
11/09/2006
Field of Education
040301 - Building Science And Technology
Original Release Date
11/09/2006
Nominal Hours
36
Description
This unit covers inspecting and preparing the erection site and erecting structures.
Notes
Elements and Performance Criteria
1. Inspect and prepare erection site
- 1.1. Site is checked for correct location, dimensions and levels.
- 1.2. Non-compliance with specifications is reported to appropriate authority.
- 1.3. Minor alterations, corrections or adjustments are undertaken with approval of appropriate authority.
- 1.4. All surfaces and materials/components are prepared for use.
- 1.5. Structure components are identified and checked against specifications.
2. Erect structures
- 2.1. All work is carried out safely and in accordance with defined procedures.
- 2.2. Structure components are prepared for correct sequential erection.
- 2.3. Components are erected and fixed according to specifications.
- 2.4. Structures are adjusted to specifications.
- 2.5. All reports and documentation are completed correctly to required specifications.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Site
Onsite or offsite locations not covered by Unit 5.11A (Assemble fabricated components)
Levels
Straightforward levelling and alignment using plumb bob/lines, levels etc.
Appropriate authority
Site supervisor, building inspector, contractor, etc.
Materials/components
Ferrous and non-ferrous materials of a:
variety of material sizes
variety of borne loads
variety of joining systems
variety of component profiles
Prepared
Cleaning
Assembly sequencing
Surface finishing
Structures
Metal frameworks, portals, stairways, walkways, vessels, tanks, platforms, conveyors and moving lines etc., including associated railings
Reports and documentation
Contract documents
Building inspection documentation
Compliance reports
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Site
Onsite or offsite locations not covered by Unit 5.11A (Assemble fabricated components)
Levels
Straightforward levelling and alignment using plumb bob/lines, levels etc.
Appropriate authority
Site supervisor, building inspector, contractor, etc.
Materials/components
Ferrous and non-ferrous materials of a:
variety of material sizes
variety of borne loads
variety of joining systems
variety of component profiles
Prepared
Cleaning
Assembly sequencing
Surface finishing
Structures
Metal frameworks, portals, stairways, walkways, vessels, tanks, platforms, conveyors and moving lines etc., including associated railings
Reports and documentation
Contract documents
Building inspection documentation
Compliance reports
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to inspect and ensure compliance of erection site and erect structures. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with assembly and erection of structures or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to inspect and ensure compliance of erection site and erect structures. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with assembly and erection of structures or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W0839 | MEM10.1AB | Erect structures | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAV82 | MEM10001 | Erect structures | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| W245 | MEM40105 | Certificate IV in Engineering | Qualification |
| W247 | MEM50105 | Diploma of Engineering - Advanced Trade | Qualification |
| W238 | MEM30305 | Certificate III in Engineering - Fabrication Trade | Qualification |
| W726 | LMT31909 | Certificate III in Engineering - TCF Mechanic | Qualification |