Unit of competency Outline
Date retreived
22/07/2026 11:48 PM AWST
22/07/2026 11:48 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Monitor, operate and control chloramination disinfection processes
Monitor, operate and control chloramination disinfection processes
Unit of competency
National Code
NWP366A
NWP366A
State Code
D1941
D1941
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
14/01/2009
Field of Education
030907 - Water And Sanitary Engineering
Original Release Date
14/01/2009
Nominal Hours
40
Description
This unit of competency describes the outcomes required to monitor, operate and control chloramination processes; and to measure and report on system performance and process quality control. The ability to identify faults, determine and apply technical adjustments and produce technical reports are essential to performance.
Notes
Elements and Performance Criteria
1Monitor chloramination process performance.
- 1.1 Conduct and analyse process tests and compare performance to plant operational requirements.
- 1.2 Identify and report process faults and the operational condition of plant according to organisational and statutory requirements.
2Operate and control chloramination processes.
- 2.1 Carry out routine plant inspections out according to organisational and plant requirements.
- 2.2 Make process adjustments to optimise system performance according to organisational requirements.
- 2.3 Collect, interpret and record process data according to organisational and plant requirements.
3Prepare and apply chloramination chemical dosing.
- 3.1 Use, handle and store chemicals according to organisational requirements.
- 3.2 Prepare chemical dosing according to system specifications and organisational requirements.
- 3.3 Maintain information related to chlorine and ammonia supply and usage according to organisational requirements.
4Compile chloramination process reports.
- 4.1 Compile reports from plant and system data to meet organisational requirements.
- 4.2 Report observations outside defined parameters for further action.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the Performance Criteria, is detailed below. Add any essential operating conditions that may be present with training and assessment depending on the work situation, needs if the candidate, accessibility of the item, and local industry and regional contexts.
Tests may include:
chlorine residual analysis, including:
total residual chlorine
monochloramine
dichloramine
ammonia and hypochlorite strength
pH
Organisational and statutory requirements may include:
by-laws and organisational policies
standard operating procedures
environment protection
occupational health and safety, including use of personal protective equipment
Australian Drinking Water Guidelines
National Water Quality Management Strategy
hazardous substances
lifts and cranes
World Health Organisation standards
licensing agreements
Environment Protection Authority regulations
Routine inspection of plant may include:
use of equipment, including:
electronic monitoring and metering systems
chart recording systems
basic hand tools
sampling and laboratory testing equipment
computerised equipment
personal protective equipment
interaction and communication with other employees, other authorities and the general public
visual observation
implementation of reporting procedures that may also include procedures for the implementation of by-laws, organisational policies and statutory requirements
Process adjustments may include:
flow rate
chlorine feed rate
ammonia feed rate
chlorine to ammonia ratio
calibration of chemical dosing equipment
Chemicals may include:
liquefied chlorine gas
sodium hypochlorite
anhydrous ammonia
aqua ammonia
pH correcting chemicals such as lime soda ash, sodium hydroxide
Reports may include:
organisational reports
environmental reports
chemical usage
plant performance data
Tests may include:
chlorine residual analysis, including:
total residual chlorine
monochloramine
dichloramine
ammonia and hypochlorite strength
pH
Organisational and statutory requirements may include:
by-laws and organisational policies
standard operating procedures
environment protection
occupational health and safety, including use of personal protective equipment
Australian Drinking Water Guidelines
National Water Quality Management Strategy
hazardous substances
lifts and cranes
World Health Organisation standards
licensing agreements
Environment Protection Authority regulations
Routine inspection of plant may include:
use of equipment, including:
electronic monitoring and metering systems
chart recording systems
basic hand tools
sampling and laboratory testing equipment
computerised equipment
personal protective equipment
interaction and communication with other employees, other authorities and the general public
visual observation
implementation of reporting procedures that may also include procedures for the implementation of by-laws, organisational policies and statutory requirements
Process adjustments may include:
flow rate
chlorine feed rate
ammonia feed rate
chlorine to ammonia ratio
calibration of chemical dosing equipment
Chemicals may include:
liquefied chlorine gas
sodium hypochlorite
anhydrous ammonia
aqua ammonia
pH correcting chemicals such as lime soda ash, sodium hydroxide
Reports may include:
organisational reports
environmental reports
chemical usage
plant performance data
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The candidate should demonstrate the ability to monitor, operate and control chloramination systems, including:
analysing tests
identifying and reporting process and operational faults
monitoring chloramination systems
making appropriate system adjustments
collecting and reporting process data
preparing and applying chloramination chemical dosing.
producing reports.
Context of and specific resources for assessment
Access to the workplace and resources including:
documentation that should normally be available in a water industry organisation
relevant codes, standards, and government regulations
Where applicable, physical resources should include equipment modified for people with disabilities.
Access must be provided to appropriate learning and/or assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the language and literacy capacity of the candidate and the work being performed.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice
a decision of competence should only be made when the assessor has complete confidence in the person's competence over time and in various contexts
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence
where assessment is for the purpose of recognition (RCC/RPL), the evidence provided will need to be authenticated and show that it represents competency demonstrated over a period of time
assessment can be through simulated project-based activity and must include evidence relating to each of the elements in this unit
In all cases where practical assessment is used it will be combined with targeted questioning to assess the underpinning knowledge. Questioning will be undertaken in a manner appropriate to the skill levels of the operator, any cultural issues that may affect responses to the questions, and reflecting the requirements of the competency and the work being performed.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The candidate should demonstrate the ability to monitor, operate and control chloramination systems, including:
analysing tests
identifying and reporting process and operational faults
monitoring chloramination systems
making appropriate system adjustments
collecting and reporting process data
preparing and applying chloramination chemical dosing.
producing reports.
Context of and specific resources for assessment
Access to the workplace and resources including:
documentation that should normally be available in a water industry organisation
relevant codes, standards, and government regulations
Where applicable, physical resources should include equipment modified for people with disabilities.
Access must be provided to appropriate learning and/or assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the language and literacy capacity of the candidate and the work being performed.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice
a decision of competence should only be made when the assessor has complete confidence in the person's competence over time and in various contexts
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence
where assessment is for the purpose of recognition (RCC/RPL), the evidence provided will need to be authenticated and show that it represents competency demonstrated over a period of time
assessment can be through simulated project-based activity and must include evidence relating to each of the elements in this unit
In all cases where practical assessment is used it will be combined with targeted questioning to assess the underpinning knowledge. Questioning will be undertaken in a manner appropriate to the skill levels of the operator, any cultural issues that may affect responses to the questions, and reflecting the requirements of the competency and the work being performed.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AVY05 | NWPTRT054 | Operate and control chloramination processes | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| D245 | NWP30107 | Certificate III in Water Operations | Qualification |