Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Perform a fluorescence test on seeds
Perform a fluorescence test on seeds
Unit of competency
National Code
AHCSDT303
AHCSDT303
State Code
BAT32
BAT32
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
12/01/2017
Field of Education
019909 - Laboratory Technology
Original Release Date
12/01/2017
Nominal Hours
35
Description
This unit of competency describes the skills and knowledge required to perform tests that determine the presence of seeds of annual ryegrass species in seedlots of perennial ryegrass. It applies to seed analysts working within enterprise requirements and procedures.It applies to individuals who take responsibility for their own work and for the quality of the work of others. They use discretion and judgement in the selection, allocation and use of available resources. All work is carried out to comply with workplace procedures.No occupational licensing, legislative or certification requirements are known to apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1. Prepare for a fluorescence test
- 1.1 Identify seed to be tested and complete records
- 1.2 Prepare working sample from submitted sample
- 1.3 Prepare the required number of replicates of 100 seeds
- 1.4 Prepare substrate as prescribed for a germination test using dormancy breaking treatments if necessary
- 1.5 Place replicates in a germination cabinet/room
2. Assess germinated seeds
- 2.1 Count off and record all un-germinated seeds and abnormal seedlings
- 2.2 Examine normal seedlings under ultra violet light
- 2.3 Count off and record normal seedlings that have fluorescent roots under ultra violet light
- 2.4 Count off and record normal seedlings that do not have fluorescent roots under ultra violet light
- 2.5 Minimise exposure of bare skin to ultra violet light
- 2.6 Complete enterprise worksheet
3. Maintain a safe work environment
- 3.1 Record, calculate and report results of test
- 3.2 Collect and dispose of laboratory and hazardous waste safely
- 3.3 Clean and store apparatus and equipment
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WE650 | AHCSDT303A | Perform a fluorescence test on seeds | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| ODU41 | AHCSDT308 | Perform tests for quality on seeds | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BDA1 | AHC33516 | Certificate III in Seed Testing | Qualification |