Unit of competency Outline

Date retreived
22/07/2026 4:34 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Fabricate and install external flashings

Fabricate and install external flashings

Unit of competency
National Code
CPCPRF3013A
State Code
D7486
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
19/05/2011
State Implementation and Classification
Approved Date
11/10/2011
Field of Education
030707 - Metal Fitting, Turning And MacHining
Original Release Date
11/10/2011
Nominal Hours
36
Description
This unit of competency specifies the outcomes required to fabricate and install external flashings for roof and ceiling systems.
Notes
Elements and Performance Criteria
1. Prepare for work.
  • 1.1. Plans and specifications are obtained and confirmed by site inspection.
  • 1.2. Safety (OHS) requirements associated with fabricating and installing external flashings, and workplace environmental requirements, are adhered to throughout the work.
  • 1.3. Quality assurance requirements are identified and adhered to in accordance with workplace requirements.
  • 1.4. Tasks are planned and sequenced in conjunction with others involved in or affected by the work and statutory and regulatory authority requirements.
  • 1.5. Tools and equipment, including personal protective equipment, are selected and checked for serviceability.
  • 1.6. Work area is prepared to support efficient fabrication and installation of external flashings.
2. Identify installation requirements.
  • 2.1. External flashings to be installed are identified and working drawings and patterns are developed from job drawings, plans, specifications, site measurements and relevant information.
  • 2.2. Materials, coatings, fixings, sealants and fasteners are checked for compliance with plans, specifications and standards and are compatible with adjacent materials and catchment.
  • 2.3. Materials are identified, ordered and collected in accordance with workplace procedures.
  • 2.4. Materials and equipment are checked for compliance with docket and order form and for acceptable condition, and faults are reported.
3. Fabricate and install external flashings.
  • 3.1. External flashings are fabricated in compliance with standards, drawings, specifications and site measurements.
  • 3.2. Support framework is set out where required and fixed to comply with plans, specifications and manufacturer recommendations.
  • 3.3. Thermal insulation, where required, is set and fixed in accordance with plans, specifications and cladding manufacturer's recommendations.
4. Clean up.
  • 4.1. Work area is cleared and materials disposed of or recycled in accordance with state and territory legislation and workplace procedures.
  • 4.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.
  • 4.3. Documentation is completed in accordance with workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Statutory and regulatory authorities include:
state or territory statutory authority
statutory plumbing authority.
Tools and equipment may include:
hand and power tools
ladders
levelling equipment,
lifting and load shifting equipment, including:
chain blocks
cranes
elevated work platforms
forklifts
hand trolleys
hoists and jacks
restricted height scaffolds
rollers
measuring equipment
perimeter guard rails.
External flashings include:
metal ceilings
associated soffits and fascias.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
regulatory and legislative requirements, particularly those pertaining to:
building codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to fabricating and installing external flashings
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Materials for fabricating and installing external flashings may include:
blankets and batts
cappings
flashings
insulation materials, such as foil laminate
lead
metal rainwater goods
metal self drilling and tapping screws
moulds
rivets and sealants
trims
other approved materials.
Fault reporting:
may be written or verbal
is to be in accordance with company's workplace procedures.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to the fabrication and installation of external flashings
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications:
fabricate and install a minimum of 2 square metres of metal ceiling and associated soffits
fabricate and install metal flashings to include an apron, parapet, apron wall, hanging and step, each up to a length of 1.5 metres
install a metal fascia up to 2 metres in length, including one external angle and one internal angle
all fabrication and installation, ensuring:
correct identification of requirements and details of the proposed installations
correct fit of the completed installation
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
State Code National Code Title Type
W9746 CPCPRF3003A Fabricate and install external flashings Unit of competency
Replaced By
State Code National Code Title Type
WF952 CPCPRF3023A Fabricate and install external flashings Unit of competency
State Code National Code Title Type
D388 CPC20811 Certificate II in Metal Roofing and Cladding Qualification