Unit of competency Outline

Date retreived
23/07/2026 1:22 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Troubleshoot basic amplifier circuits

Troubleshoot basic amplifier circuits

Unit of competency
National Code
UEEEC0067
State Code
OBX55
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
05/10/2020
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031317 - Electronic Equipment Servicing
Original Release Date
12/07/2021
Nominal Hours
36
Description
This unit involves the skills and knowledge required to troubleshoot basic amplifier circuits. It includes preparing to troubleshoot basic amplifiers, solving basic amplifier circuit problems, completing work and reporting on problem-solving activities.Permits may be required for some work environments, such as confined spaces, working aloft, near live electrical apparatus and site rehabilitationNo licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to troubleshoot basic amplifiers
  • 1.1 Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for relevant work area are identified, obtained and applied
  • 1.2 WHS/OHS risk control measures are applied in accordance with workplace procedures prior to commencing work
  • 1.3 Scope of the fault is obtained from documentation or discussions with relevant person/s to determine scope of work
  • 1.4 Instructions for coordinating work with others are obtained from relevant person/s and applied
  • 1.5 Materials required for work are determined in accordance with workplace procedures
  • 1.6 Tools, equipment and testing devices required for work are obtained and checked for correct operation and safety
2 Solve basic amplifier circuit problems
  • 2.1 WHS/OHS risk control measures and workplace procedures are applied
  • 2.2 Need to test and measure live work is determined in accordance with WHS/OHS requirements and workplace procedures
  • 2.3 Circuits are isolated, as necessary, in accordance with WHS/OHS requirements and workplace procedures
  • 2.4 Fault finding is undertaken methodically applying principles of basic amplifiers and using measured and calculated values of parameters
  • 2.5 Unexpected situations are dealt with safely and with the approval of relevant person/s
  • 2.6 Fault-finding activities are conducted efficiently minimising unnecessary waste of materials, damage to apparatus, the surrounding environment or services applying sustainable energy practices
3 Complete work and report on problem-solving activities
  • 3.1 WHS/OHS risk control measures and procedures are applied
  • 3.2 Worksite is cleaned and made safe in accordance with workplace procedures
  • 3.3 Justification for troubleshooting solutions is provided in the required format
  • 3.4 Work completion is reported and relevant person/s notified in accordance with workplace procedures
No information
No information
Replaces
State Code National Code Title Type
WC567 UEENEEH139A Troubleshoot basic amplifier circuits Unit of competency