Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Design hydrodynamic pumping systems
Design hydrodynamic pumping systems
Unit of competency
National Code
MEM234005A
MEM234005A
State Code
S8100
S8100
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
29/08/2014
Field of Education
030701 - Mechanical Engineering
Original Release Date
29/08/2014
Nominal Hours
54
Description
This unit of competency covers the design of new or modified hydrodynamic pumping systems, including the layout; choice of motor and pumps, pipes and valves; the fluid source and delivery requirements of the system. It includes sustainability implications, occupational health and safety (OHS) and regulatory requirements.
Notes
Elements and Performance Criteria
1 Clarify the design brief and elaborate the specification
- 1.1 Establish required features and performance parameters of hydrodynamic pumping system
- 1.2 Confirm technical, commercial and environmental parameters to the brief or contract
- 1.3 Determine stakeholders to be consulted in design process
- 1.4 Assess OHS, regulatory, sustainability or environmental issues relevant to the design task
- 1.5 Confirm design brief, including budget and schedule, and provide preliminary advice on feasibility
2 Evaluate design analysis and prepare concept proposals
- 2.1 Appraise initial qualitative and quantitative analysis of the design task
- 2.2 Carry out required detailed modelling and calculations using appropriate software and validation techniques
- 2.3 Generate a range of solutions to the design brief, including choice of equipment, layout, fluid source and delivery
- 2.4 Check feasibility and evaluate solutions against design criteria ensuring conformity to standards and codes, technical, economic and OHS requirements
- 2.5 Determine, social and sustainability implications of solutions
- 2.6 Present concept proposals to client
3 Design hydrodynamic pumping system
- 3.1 Evaluate concept proposals with client
- 3.2 Ensure that design solution is optimised with respect to the system specifications
- 3.3 Finalise selected design, including equipment, layout, fluid source and delivery, and other features desired by client
- 3.4 Ensure preparation of all required documentation, drawings, specifications and instructions
- 3.5 Consult with client and stakeholders to obtain sign-off on design
- 3.6 Monitor installation and commissioning with stakeholders and make any necessary adjustments to design
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Parameters to the design brief
The design brief may include the design of new equipment or fault analysis, rectification or modification to an existing design. Parameters to the design brief may include:
These may include:
determination of the degree of innovation and creativity expected by the client
design process limits and budgets
product cost limits and budgets
performance specification
equipment availability, capacities and restrictions
specified administrative, communication and approval procedures
other special features and limits in the design brief
OHS, regulatory, sustainability and environmental issues
OHS, regulatory, sustainability and environmental issues may include:
OHS Acts and regulations
relevant standards
industry codes of practice
risk assessments
registration requirements
safe work practices
minimising ecological and environmental footprint of process, plant and product
maximising economic benefit of process plant and product to the organisation and the community
minimising the negative OHS impact on employees, community and customer
state and territory regulatory requirements
Client
Client may be:
internal or external to the designer’s organisation
Range of solutions
Range of solutions may include those that:
satisfy the technical requirements of the design brief
are within budget
are able to be manufactured
meet any regulatory requirements
minimise environmental and sustainability impacts
Standards and codes
Standards and codes refer to all relevant Australian and international standards and codes applicable to a particular design task
System specifications
System specifications may include, but are not limited to:
pump types
system head requirements
pump performance requirements
duty point
flow rates
cavitation issues and control
power and efficiency
energy cost of pumping
valves for flow control
component layout
Parameters to the design brief
The design brief may include the design of new equipment or fault analysis, rectification or modification to an existing design. Parameters to the design brief may include:
These may include:
determination of the degree of innovation and creativity expected by the client
design process limits and budgets
product cost limits and budgets
performance specification
equipment availability, capacities and restrictions
specified administrative, communication and approval procedures
other special features and limits in the design brief
OHS, regulatory, sustainability and environmental issues
OHS, regulatory, sustainability and environmental issues may include:
OHS Acts and regulations
relevant standards
industry codes of practice
risk assessments
registration requirements
safe work practices
minimising ecological and environmental footprint of process, plant and product
maximising economic benefit of process plant and product to the organisation and the community
minimising the negative OHS impact on employees, community and customer
state and territory regulatory requirements
Client
Client may be:
internal or external to the designer’s organisation
Range of solutions
Range of solutions may include those that:
satisfy the technical requirements of the design brief
are within budget
are able to be manufactured
meet any regulatory requirements
minimise environmental and sustainability impacts
Standards and codes
Standards and codes refer to all relevant Australian and international standards and codes applicable to a particular design task
System specifications
System specifications may include, but are not limited to:
pump types
system head requirements
pump performance requirements
duty point
flow rates
cavitation issues and control
power and efficiency
energy cost of pumping
valves for flow control
component layout
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently:
interpret features of plant and equipment and parameters to the brief or contract
advise client based on discipline knowledge and OHS and regulatory standards
research sustainability implications and current industrial design techniques
determine OHS, regulatory and risk management requirements
investigate and measure
model and calculate using appropriate software and validation techniques
generate and evaluate a range of solutions for feasibility against design criteria
design hydrodynamic pumping solution
communicate, negotiate and review with stakeholders and client throughout process to obtain agreement on proposal and sign-off on design
document design with drawings, specifications and instructions.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is, the candidate is not in productive work, then a simulated working environment must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate ethnicity, age, gender, demographics and disability.
Access must be provided to appropriate learning and/or assessment support when required. Where applicable, physical resources should include equipment modified for people with disabilities.
Method of assessment
Assessment must satisfy the endorsed Assessment Guidelines of the MEM05 Metal and Engineering Training Package.
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge.
Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure its correct interpretation and application.
Assessment may be applied under project-related conditions (real or simulated) and require evidence of process.
Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances.
Assessment may be in conjunction with assessment of other units of competency where required.
Guidance information for assessment
Assessment processes and techniques must be culturally appropriate and appropriate to the language and literacy capacity of the candidate and the work being performed.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently:
interpret features of plant and equipment and parameters to the brief or contract
advise client based on discipline knowledge and OHS and regulatory standards
research sustainability implications and current industrial design techniques
determine OHS, regulatory and risk management requirements
investigate and measure
model and calculate using appropriate software and validation techniques
generate and evaluate a range of solutions for feasibility against design criteria
design hydrodynamic pumping solution
communicate, negotiate and review with stakeholders and client throughout process to obtain agreement on proposal and sign-off on design
document design with drawings, specifications and instructions.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is, the candidate is not in productive work, then a simulated working environment must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate ethnicity, age, gender, demographics and disability.
Access must be provided to appropriate learning and/or assessment support when required. Where applicable, physical resources should include equipment modified for people with disabilities.
Method of assessment
Assessment must satisfy the endorsed Assessment Guidelines of the MEM05 Metal and Engineering Training Package.
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge.
Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure its correct interpretation and application.
Assessment may be applied under project-related conditions (real or simulated) and require evidence of process.
Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances.
Assessment may be in conjunction with assessment of other units of competency where required.
Guidance information for assessment
Assessment processes and techniques must be culturally appropriate and appropriate to the language and literacy capacity of the candidate and the work being performed.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OEW94 | MEM234005 | Design hydrodynamic pumping systems | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J482 | MEM80112 | Graduate Diploma of Engineering | Qualification |