Qualification Outline

Date retreived
22/07/2026 5:39 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Certificate IV in Rail Signalling

Certificate IV in Rail Signalling

Qualification
National Code:
UEE41223
State Code:
BJD4
TGA Status:
Current
DTWD Status:
Approved
National Endorsed, State Implementation and Classification
Field of Education
0313 - Electrical And Electronic Engineering And Technology
Original TGA Release Date
08/02/2023
Approved Date
19/04/2023
Stream of Study
Initial Vocational (3100 - 3600)
VET Act Classifier
C
Nominal Hours
459
Duration
1 Semester
Current Release Number
1.00
Current Release Date
08/02/2023
VET Act Conditions
Releases
Release Version Release Date TGA Status DTWD Status
1.00 08/02/2023 Current Approved
Description

This qualification provides competencies to install, certify, fault find and maintain rail signalling equipment and systems.
This includes requirements for performing like-for-like replacement, performing authorised installations and alterations, and applying emergency operational restriction. It excludes changing circuit principles, changing the design function and commissioning.
No licensing, legislative or certification requirements apply to this qualification at the time of publication.

Schedule
Packaging Rules
A minimum of 510 weighting points comprising:
- 390 core weighting points listed below; plus
- minimum of 120 general elective weighting points from the general elective units listed below.

Choose a minimum of 120 weighting points elective units from the list below, of which:
- between 0 and 40 weighting points can be taken from Group A;
- a minimum of 40 weighting points must be taken from Group B; and,
- a minimum of 40 weighting points must be taken from Group C

Up to 30 weighting points of the general elective units Group A, may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training Package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC).

There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by an Asterix on training.gov.au (TGA). Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume.

Prerequisite units not packaged in this qualification will be met by entry requirements.

Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with.
1. Core Units

All core units must be completed.

State Code National Code Title Hours Type
OFE03 UEERS0020 Apply rail signalling principles 18 Unit of competency
OFE04 UEERS0021 Assemble and wire electrical rail signalling equipment 36 Unit of competency
OFE02 UEERS0022 Find and repair rail signalling system faults 18 Unit of competency
OCA29 UEERE0015 Implement and monitor energy sector environmental and sustainable policies and procedures 18 Unit of competency
OCA17 UEECD0024 Implement and monitor energy sector WHS policies and procedures 18 Unit of competency
OFE00 UEERS0024 Install and maintain rail track circuit leads and bonds 27 Unit of competency
OFD99 UEERS0025 Maintain active level crossing equipment 36 Unit of competency
OFD94 UEERS0030 Maintain power-operated point actuating devices 36 Unit of competency
OFD93 UEERS0031 Maintain rail signalling power supplies 36 Unit of competency
OFD92 UEERS0032 Maintain trackside signal and train protection equipment 36 Unit of competency
OFD91 UEERS0033 Maintain train detection equipment 36 Unit of competency
OCB19 UEECD0027 Participate in development and follow a personal competency development plan 18 Unit of competency
OFD87 UEERS0037 Test copper rail signalling cables 18 Unit of competency
2. Group A Elective Units

Between 0 and 40 weighting points can be taken from Group A.
Please refer to the packaging rules for the full details of available options.

State Code National Code Title Hours Type
AVJ44 TLIF2010 Apply fatigue management strategies 30 Unit of competency
OAA33 TLIF0008 Apply safety critical communications in the rail environment 25 Unit of competency
OBX53 UEECD0011 Comply with scheduled and preventative maintenance program processes 18 Unit of competency
OCD34 BSBOPS203 Deliver a service to customers 40 Unit of competency
OBY02 UEECO0002 Maintain documentation 18 Unit of competency
OBU39 ICTICT214 Operate application software packages 60 Unit of competency
ODX74 CPCWHS1001 Prepare to work safely in the construction industry 6 Unit of competency
OCA56 UEECD0035 Provide basic instruction in the use of electrotechnology apparatus 18 Unit of competency
OCD26 HLTAID009 Provide cardiopulmonary resuscitation 4 Unit of competency
OBY92 UEECO0015 Provide quotations for installation or service jobs 18 Unit of competency
OCZ04 TLIF0020 Safely access the rail corridor 10 Unit of competency
OBY79 UEECO0017 Source and purchase material/parts for installation or service jobs 18 Unit of competency
OBW40 RIIWHS204E Work safely at heights 16 Unit of competency
3. Group B Elective Units

A minimum of 40 weighting points must be taken from Group B.
Please refer to the packaging rules for the full details of available options.

State Code National Code Title Hours Type
OFD96 UEERS0027 Maintain computer-based interlocking rail systems 27 Unit of competency
OFD89 UEERS0034 Maintain vital relay interlocking systems 36 Unit of competency
4. Group C Elective Units

A minimum of 40 weighting points must be taken from Group C.
Please refer to the packaging rules for the full details of available options.

State Code National Code Title Hours Type
OBX38 UEECS0003 Assemble, set up and test computing devices 72 Unit of competency
OFE01 UEERS0023 Inspect, test and certify rail power signal equipment 18 Unit of competency
OFD98 UEERS0026 Maintain communications based signalling equipment 18 Unit of competency
OFD96 UEERS0027 Maintain computer-based interlocking rail systems 27 Unit of competency
OFD97 UEERS0028 Maintain mechanical rail signalling equipment and infrastructure 18 Unit of competency
OFD95 UEERS0029 Maintain non-vital telemetry systems 36 Unit of competency
OFD89 UEERS0034 Maintain vital relay interlocking systems 36 Unit of competency
OFD90 UEERS0035 Maintain wayside asset protection equipment 18 Unit of competency
OFD88 UEERS0036 Repair rail signalling power and control cables 36 Unit of competency
OBZ30 UEECS0029 Set up and configure basic local area network (LAN) 72 Unit of competency
Replaces
State Code National Code Title Type
BFO2 UEE41220 Certificate IV in Electrical - Rail Signalling Qualification
No information
Entry Requirements

There are two entry requirement pathways for this qualification. All relevant jurisdictional licencing requirements must be complied with in the first instance. These requirements will determine the pathway that is applicable and must be selected, and how qualification certification documentation is completed. See notes below.
Entry requirement pathways for this qualification are as follows:
Certificate III in Electrotechnology Electrician; or, a current ‘Unrestricted Electricians Licence’ or its equivalent issued in an Australian state or territory
or
Certificate III in Electrical Fitting
Note: The Certificate III in Electrical Fitting qualification must not be used as the entry requirement in jurisdictions where industry and/or regulatory arrangements require a current ‘Unrestricted Electricians Licence’ or its equivalent issued in an Australian state or territory to undertake rail signalling installation and/or maintenance.
Note: Qualification certification documentation (testamur) must indicate which pathway was used as follows:
If Certificate III in Electrotechnology Electrician or, a current ‘Unrestricted Electricians Licence’ is used the qualification title should appear on certification documentation as: UEE41223 Certificate IV in Rail Signalling (Electrotechnology Electrician)
If Certificate III in Electrical Fitting is used the qualification title should appear on certification documentation as: UEE41223 Certificate IV in Rail Signalling (Electrical Fitting)
Note: UEE41223 Certificate IV in Electrical - Rail Signalling can be undertaken in conjunction with either of the entry requirement qualifications listed above as long as the following conditions are met:
must be permitted within jurisdictional training and regulatory requirements;
at least one third of the total weighting points required for completion of the entry requirement qualification must be met prior to commencing the Certificate IV in Electrical - Rail Signalling; and,
the relevant Certificate III entry requirement qualification must be successfully completed prior to issuing the Certificate IV in Electrical - Rail Signalling.

Traineeships and Apprenticeships
No information