Unit of competency Outline

Date retreived
22/07/2026 9:13 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Inspect sub-floors

Inspect sub-floors

Unit of competency
National Code
LMFFC3001A
State Code
W0193
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
11/05/2009
State Implementation and Classification
Approved Date
09/12/2003
Field of Education
040321 - Floor Coverings
Original Release Date
09/12/2003
Nominal Hours
20
Description
Notes
Elements and Performance Criteria
No information
The Range Statement provides advice to interpret the scope and context of this unit of competency, allowing for differences between enterprises and workplaces. It relates to the unit as a whole and facilitates holistic assessment. The following variables may be present for this particular unit:

Floor inspection scope

This unit covers work involving the trade level inspection of timber and concrete floors and sub-floor areas in accordance with relevant Australian Standards to identify and notify on the suitability for floor coverings

It does not confer authority or, of itself, satisfy formal requirements which may be established by regulatory authorities or agencies

Unit context

OH&S requirements may include legislation, building codes, material safety management systems, hazardous substance and dangerous goods codes and local safe operating procedures

Work is carried out in accordance with legislative obligations, environmental legislation, relevant health regulations, manual handling procedures and organisation insurance requirements

Work requires individuals to demonstrate discretion, judgement and problem solving skills in inspecting and notifying suitability of sub-floors to receive floor coverings

Tools and equipment are to include:

3m straight edge

1.5m straight edge

150mm straight edge

spirit level

string line

chalk line

electrical resistance meter

tape measure

electric drill and masonry drill bits

Tools and equipment may include:

water/laser level

hygrometer

thermometer probe and acid and alkaline testing equipment

Materials

Timber strip flooring, construction sheet flooring, monolithic floors, above grade, on grade and below grade floor

Datum line checks

Datum line checks are used to confirm floor fall, dips and irregularities and finished floor height in relation to other floor coverings and door clearances

Timber flooring inspections are to include:

tests for moisture content

protruding nails

loose metal and other objects

cracked

loose or damaged boards

rotting

insect attack and cross flow ventilation

Concrete floor inspections are to include:

checks for any protruding obstacles

for cracks or damage and for moisture membrane existence

Inspection notifications are to cover:

the type of the inspection completed

testing methods used

findings of inspection

suggested remedies to any faults identified and recommendations for floor coverings or finishing

Personal protective equipment

Personal protective equipment is to include that prescribed under legislation, regulations and enterprise policies and practices

Information and procedures

Workplace procedures relating to the use and operation of tools and equipment

Workplace instructions, including job sheets, plans, drawings and designs

Workplace procedures relating to notification and communications

Manufacturers' instructions for the use of equipment and materials

The Evidence Guide identifies the critical aspects, knowledge and skills to be demonstrated to confirm competency for this unit. This is an integral part of the assessment of competency and should be read in conjunction with the Range Statement.
Critical Aspects of Evidence
Interpret work order and locate and apply relevant information
Apply safe handling requirements for equipment, products and materials, including use of personal protective equipment
Follow work instructions, operating procedures and inspection practices to:
minimise the risk of injury to self and others
prevent damage to goods, equipment and products
maintain required production output and product quality
To complete a minimum of:
One timber floor inspection and written notification
One monolithic floor inspection and written notification
Work effectively with others
Modify activities to cater for variations in workplace contexts and environment

Underpinning Knowledge
The type, characteristics and defects of floor structures
The requirements for floor condition for floor coverings
The characteristics and requirements of sub-floor preparation
The methods of correcting defects
Workflow in relation to floor covering and inspection processes and procedures
Workplace safety system requirements related to floor inspection and floor covering

Underpinning Skills
Information. Collect, organise and understand information related to work orders, plans, and safety procedures
Communication. Communicate ideas and information to enable confirmation of work requirements and specifications, coordination of work with site supervisor, other workers and customers, and the notification of work outcomes and problems
Planning. Plan and organise activities including the preparation and layout of the worksite and the obtaining of equipment and materials to avoid any back tracking, workflow interruptions or wastage
Teamwork. Work with others and in a team by recognising dependencies and using cooperative approaches to optimise workflow and productivity
Mathematical ideas and techniques. Use mathematical ideas and techniques to correctly complete measurements, complete datum checks, calculate area and estimate material requirements
Solve problems. Use pre-checking and inspection techniques to anticipate inspection problems, avoid reworking and avoid wastage
Use of technology. Use workplace technology related to the inspection of floors including tools, equipment and measuring devices

Resource Implications
Range of floor types and conditions, test equipment, work order.

Method of Assessment
Assessment methods must confirm consistency of performance over time and in a range of workplace relevant contexts.
Assessment should be by direct observation of tasks and questioning on underpinning knowledge.
Assessment may be in conjunction with assessment of other relevant units of competency.

Context of Assessment
Assessment may occur on the job or in a workplace simulated facility with relevant floor inspection materials, work instructions and deadlines.

Key Competency Levels
NB:These levels do not relate to the Australian Qualifications Framework. They relate to the seven areas of generic competency that underpin effective workplace practices.
There are three levels available:
Level 1 where work is within set conditions and process
Level 2 where the management or facilitation of conditions or process is exercised; and
Level 3 where the design and/or development of conditions or process is required
Communicating ideas and information
(2)

Collecting analysing and organising information
(2)

Planning and organising activities
(2)

Working with others and in teams
(1)

Using mathematical ideas and techniques
(1)

Solving problems
(1)

Using technology
(1)

Replaced By
State Code National Code Title Type
W8582 LMFFL3504A Inspect defective timber flooring Unit of competency
W8553 LMFFL3101A Inspect sub-floors Unit of competency
State Code National Code Title Type
W021 LMF20102 Certificate II in Floor Covering and Finishing Qualification