Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Inspect defective timber flooring
Inspect defective timber flooring
Unit of competency
National Code
LMFFL3504A
LMFFL3504A
State Code
W8582
W8582
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
08/04/2011
Field of Education
040321 - Floor Coverings
Original Release Date
08/04/2011
Nominal Hours
20
Description
This unit specifies the outcomes required to prepare for, carry out, and report on inspections on defective timber flooring.
Notes
Elements and Performance Criteria
1. Plan and prepare for the inspection
- 1.1. Applicable legislative, OHS and organisational requirements relevant to the inspection of timber flooring are verified and complied with
- 1.2. Workplace health and safety requirements, including personal protection needs, are observed throughout the work
- 1.3. The purpose, scope, formality and reporting requirements for the inspection are identified, clarified and agreed
- 1.4. The need for and liability associated with for the outcome of invasive inspection techniques are documented and agreed
- 1.5. Tools, equipment and materials required for the inspection are selected and checked prior to use to ensure that they are appropriate for the work and in a safe condition
- 1.6. Sequence of work is planned to ensure efficiency and quality of outcome
2. Conduct the inspection
- 2.1. Initial visual and other non-invasive inspections are completed to identify and isolate further inspection needs
- 2.2. Finishing faults and remedial options are identified and analysed
- 2.3. Structural faults and remedial options are identified and analysed
- 2.4. Material faults including infestation and moisture effects and remedial options are identified and analysed
- 2.5. Sub-floor faults, their impacts and remedial options are identified and analysed
- 2.6. Areas invasively inspected are made safe
3. Report on the inspection
- 3.1. The inspection report addresses the agreed terms of reference
- 3.2. The report clearly identifies the scope of the inspection, the findings and the suggested options for addressing the faults or findings
- 3.3. The report is presented to the client together with any required clarification
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Legislative requirements
are to be in accordance with applicable legislation from all levels of government that affect organisational operation. Requirements may include but not be limited to award and enterprise agreements, industrial relations, Australian Standards, confidentiality and privacy, OHS, the environment, equal opportunity, anti-discrimination, relevant industry codes of practice, duty of care and heritage
OHS requirements
are to be in accordance with Commonwealth, State or Territory legislation and regulations, organisational safety policies and procedures. Requirements may include but not be limited to the use of personal protective equipment and clothing, fire fighting equipment, First Aid equipment, hazard and risk control and elimination, control of hazardous materials and substances, manual handling including lifting and carrying
Organisational requirements
may include but not be limited to legal, organisational and site guidelines, policies and procedures relating to own role and responsibility, quality assurance, procedural manuals, quality and continuous improvement processes and standards, OHS, emergency and evacuation, ethical standards, recording and reporting, access and equity principles and practices, equipment use, maintenance and storage, environmental management (waste disposal, recycling and re-use guidelines)
Invasive inspection techniques
are those which require significant removal of coatings and materials and where restoration is required, regardless of the inspection finding
Finishing faults
may include contaminated coating (dust, foreign objects), coating rejection, incorrect coating, swirl marks, scratches, drum marks, waves, taper tracks, striations, rippers, chatter marks and edgebonding
Structural faults
may include splits, cracks, broken boards, failed fixings and incorrect board size
Materials faults
may include warp, wane, curvature, shakes, insect defects, knots and resin pockets
Sub-floor faults
may include incorrect levels, soundness and moisture
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Legislative requirements
are to be in accordance with applicable legislation from all levels of government that affect organisational operation. Requirements may include but not be limited to award and enterprise agreements, industrial relations, Australian Standards, confidentiality and privacy, OHS, the environment, equal opportunity, anti-discrimination, relevant industry codes of practice, duty of care and heritage
OHS requirements
are to be in accordance with Commonwealth, State or Territory legislation and regulations, organisational safety policies and procedures. Requirements may include but not be limited to the use of personal protective equipment and clothing, fire fighting equipment, First Aid equipment, hazard and risk control and elimination, control of hazardous materials and substances, manual handling including lifting and carrying
Organisational requirements
may include but not be limited to legal, organisational and site guidelines, policies and procedures relating to own role and responsibility, quality assurance, procedural manuals, quality and continuous improvement processes and standards, OHS, emergency and evacuation, ethical standards, recording and reporting, access and equity principles and practices, equipment use, maintenance and storage, environmental management (waste disposal, recycling and re-use guidelines)
Invasive inspection techniques
are those which require significant removal of coatings and materials and where restoration is required, regardless of the inspection finding
Finishing faults
may include contaminated coating (dust, foreign objects), coating rejection, incorrect coating, swirl marks, scratches, drum marks, waves, taper tracks, striations, rippers, chatter marks and edgebonding
Structural faults
may include splits, cracks, broken boards, failed fixings and incorrect board size
Materials faults
may include warp, wane, curvature, shakes, insect defects, knots and resin pockets
Sub-floor faults
may include incorrect levels, soundness and moisture
EVIDENCE GUIDE
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Comply with legislation, regulations, standards, codes of practice and established safe practices and procedures for inspecting timber flooring
Interpret work order and locate and apply relevant information
Apply safe handling requirements for equipment, products and materials, including use of personal protective equipment
Follow work instructions, operating procedures and inspection practices to:
minimise the risk of injury to self and others
prevent damage to goods, equipment and products
maintain required production output and product quality
Inspect and correctly report on two timber floors where one requires invasive inspection techniques
Work effectively with others
Modify activities to cater for variations in workplace contexts and environment
Context of, and specific resources for assessment
The application of competency is to be assessed in the workplace or realistically simulated workplace
Assessment is to occur under standard and authorised work practices, safety requirements and environmental constraints
Assessment of essential underpinning knowledge, other than confirmatory questions, will usually be conducted in an off-site context
Assessment is to comply with relevant regulatory or Australian Standards requirements
The following resources should be made available:
realistic inspection requirements
a client/simulated client
workplace location or simulated workplace
materials and equipment relevant to inspection and presentation of findings
Method of assessment
Assessment must satisfy the endorsed assessment guidelines of the Furnishing Industry Training Package
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge
Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure its correct interpretation and application
Assessment may be applied under project related conditions (real or simulated) and require evidence of process
Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances
Assessment may be in conjunction with assessment of other units of competency
The Evidence Guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Comply with legislation, regulations, standards, codes of practice and established safe practices and procedures for inspecting timber flooring
Interpret work order and locate and apply relevant information
Apply safe handling requirements for equipment, products and materials, including use of personal protective equipment
Follow work instructions, operating procedures and inspection practices to:
minimise the risk of injury to self and others
prevent damage to goods, equipment and products
maintain required production output and product quality
Inspect and correctly report on two timber floors where one requires invasive inspection techniques
Work effectively with others
Modify activities to cater for variations in workplace contexts and environment
Context of, and specific resources for assessment
The application of competency is to be assessed in the workplace or realistically simulated workplace
Assessment is to occur under standard and authorised work practices, safety requirements and environmental constraints
Assessment of essential underpinning knowledge, other than confirmatory questions, will usually be conducted in an off-site context
Assessment is to comply with relevant regulatory or Australian Standards requirements
The following resources should be made available:
realistic inspection requirements
a client/simulated client
workplace location or simulated workplace
materials and equipment relevant to inspection and presentation of findings
Method of assessment
Assessment must satisfy the endorsed assessment guidelines of the Furnishing Industry Training Package
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge
Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure its correct interpretation and application
Assessment may be applied under project related conditions (real or simulated) and require evidence of process
Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances
Assessment may be in conjunction with assessment of other units of competency
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W0193 | LMFFC3001A | Inspect sub-floors | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| WI389 | MSFFL3032 | Inspect defective timber flooring | Unit of competency |