Unit of competency Outline

Date retreived
23/07/2026 2:07 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Determine the explosion-protection requirements to meet a specified classified hazardous area

Determine the explosion-protection requirements to meet a specified classified hazardous area

Unit of competency
National Code
UEEHA0022
State Code
OEE62
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
24/10/2022
State Implementation and Classification
Approved Date
10/02/2023
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
10/02/2023
Nominal Hours
36
Description
This unit involves the skills and knowledge required to determine the explosion-protection requirements to meet a specified classified hazardous area. It includes determining the type of explosion-protected equipment for a given explosive atmosphere. It also includes reading and interpreting the explosion-protection fundamentals in explosive atmosphere technical standards; understanding the information given in certification documents, verification dossiers and equipment marking; identifying the design features of each type of explosion-protected equipment; understanding actions and conditions that would void the explosion-protection afforded by each equipment type; and understanding where each equipment type may be used.This unit applies to design, installation, maintenance, inspection, auditing, and repair and overhaul functions.Site-specific work permits may be required to work in the hazardous environment. In addition, other permits may be required, such as confined space and to operate specific pieces of equipment such as elevated work platforms (EWPs) in various jurisdictions.Additional and/or other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.This unit of competency and associated assessment requirements is adopted from clause 2.4 of AS/NZS 4761.1:2018 Competencies for working with electrical equipment for hazardous areas (EEHA). There may be differences between the content of this unit and AS/NZS 4761.1:2018, so the Standard must be checked to ensure compliance with it. Clause 2.4 of AS/NZS 4761.1:2018 includes the following precondition for assessment:"A candidate seeking assessment in this unit shall have been deemed competent to install, maintain, inspect and/or engineer electrotechnology equipment and installations from AQF level 3 or NZQF level 4 or higher."
Notes
Elements and Performance Criteria
1 Prepare to review explosion-protection technical standards
  • 1.1 Technical standards specifying the requirements to which each type of explosion-protected equipment is required to comply are identified
  • 1.2 A verification dossier for a site that has gas hazards is reviewed and requirements for the explosive atmospheres are established
  • 1.3 A verification dossier for a site that has dust hazards is reviewed and requirements for the explosive atmospheres are established
2 Ascertain the requirements for each explosion-protection type
  • 2.1 Protective features of each equipment type are identified through application of knowledge of explosion-protection methods
  • 2.2 Equipment standards are reviewed to establish the compliance requirements for each equipment type
  • 2.3 Aspects that are vulnerable to voiding the protection due to defective installation or poor maintenance are determined from knowledge of equipment types and equipment standards
  • 2.4 Items of explosion-protected equipment are examined to identify any condition that would void the protection
  • 2.5 Where particular explosion-protected equipment types may be used, relevant technical standards, equipment certification and the verification dossier for a given site are established
3 Identify acceptable equipment certification
  • 3.1 Knowledge of the equipment certification process and acceptable standards are applied
  • 3.2 The required marking on certified equipment is obtained from relevant technical standards
  • 3.3 The suitability of explosion-protection equipment items for a given application and location is ascertained from relevant technical standards, certification documents, equipment marking and the verification dossier for a given site
No information
No information
State Code National Code Title Type
BFM8 UEE62220 Advanced Diploma of Electrical - Engineering Qualification
BFO8 UEE40820 Certificate IV in Electrical - Fire Protection Control Systems Qualification
BFK8 UEE40420 Certificate IV in Electrical - Instrumentation Qualification
BFK5 UEE50420 Diploma of Electrical Engineering Qualification
BFL9 UEE62320 Advanced Diploma of Electrical Engineering - Coal Mining Qualification
BOA6 UEE62325 Advanced Diploma of Electrical Engineering - Coal Mining Qualification
BFM2 UEE43020 Certificate IV in Electrical Equipment and Systems Qualification
BFO5 UEE33020 Certificate III in Electrical Fitting Qualification
BFP6 UEE53020 Diploma of Electrical Systems Engineering Qualification
BFK9 UEE63020 Advanced Diploma of Electrical Systems Engineering Qualification
BFN2 UEE40620 Certificate IV in Electrotechnology - Systems Electrician Qualification
BFN0 UEE30820 Certificate III in Electrotechnology Electrician Qualification
BHZ2 UEE61222 Advanced Diploma of Engineering - Explosion protection Qualification
BNY5 UEE31025 Certificate III in Fire Protection Control Qualification
BFO4 UEE31020 Certificate III in Fire Protection Control Qualification
BHZ9 UEE42622 Certificate IV in Hazardous areas - Electrical Qualification
BFK2 UEE40920 Certificate IV in Industrial Electronics and Control Qualification
BFL3 UEE60620 Advanced Diploma of Industrial Electronics and Control Engineering Qualification
BFM6 UEE40320 Certificate IV in Installation Inspection and Audits Qualification
BFQ5 UEE31220 Certificate III in Instrumentation and Control Qualification
BFP2 UEE42220 Certificate IV in Instrumentation and Control Qualification
BOA2 UEE31225 Certificate III in Instrumentation and Control Qualification
BHC7 UEE61521 Advanced Diploma of Instrumentation and Control Engineering Qualification
BFK6 UEE51020 Diploma of Instrumentation and Control Engineering Qualification