Unit of competency Outline

Date retreived
22/07/2026 5:07 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Solve problems in single path circuits

Solve problems in single path circuits

Unit of competency
National Code
UEECD0046
State Code
OCA07
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
05/10/2020
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
36
Description
This unit involves the skills and knowledge required to solve problems in single path circuits.It includes working safely; applying problem-solving procedures, including the use of basic voltage, current and resistance measuring devices; and providing known solutions to predictable circuit problems.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to work on single path electrical circuits
  • 1.1 Scope of work to be undertaken is determined from relevant documentation, electrical drawings or relevant person/s
  • 1.2 Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are identified and applied
  • 1.3 Electrical hazards are identified, risks are assessed, and control measures are implemented
  • 1.4 Advice is sought from the relevant person/s to ensure the work is coordinated effectively with others
  • 1.5 Materials required for work are identified and accessed in accordance with workplace procedures
  • 1.6 Tools, equipment and testing devices needed to carry out work are obtained and checked for correct operation and safety
2 Solve problems in single path electrical circuits
  • 2.1 The need to test or measure live electrical work is determined in accordance with WHS/OHS requirements and, when necessary, conducted in accordance with workplace procedures
  • 2.2 Circuits are checked as isolated in accordance with workplace procedures and regulatory requirements
  • 2.3 Expected circuit parameters are calculated from relevant component ratings/specifications
  • 2.4 Circuit parameters are measured in accordance with industry standards and checked against expected values
  • 2.5 Circuit problems are assessed using measured and calculated values as they apply to single path, single source circuits
  • 2.6 Circuit solutions are determined from measured and calculated values of resistance, voltage, current, and power in single path circuits
  • 2.7 Solutions are tested in accordance with workplace procedures and industry standards
  • 2.8 Problems are resolved without damage to equipment, circuits, the surrounding environment or services using sustainable energy practices
  • 2.9 Unplanned situations are responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
3 Complete work and document problem solving activities
  • 3.1 WHS/OHS work completion risk control measures and procedures are followed
  • 3.2 Worksite is cleaned and made safe in accordance with workplace procedures
  • 3.3 Justification for solutions used to solve circuit problems is documented
  • 3.4 Work completion is documented, and relevant personnel are notified in accordance with workplace procedures
No information
No information
No information
State Code National Code Title Type
AE230 UEESS00131 Data Communications - ACMA 'Open' Cabling Provider Skill Set Skill set
AE257 UEESS00134 Data Communications - Install Aerial Communication Cables Skill Set Skill set
AE271 UEESS00169 Data Communications - Install and Modify Performance Data Communication Structured Cabling Skill Set Skill set
AE262 UEESS00137 Data Communications - Install Below Ground Communication Cables Skill Set Skill set
AE259 UEESS00139 Data Communications - Restricted Telecommunications Cabler Registration - ACMA Skill Set Skill set
BFO0 UEE50320 Diploma of Electrical and Refrigeration and Air Conditioning Qualification
BMB4 UEE50325 Diploma of Electrical and Refrigeration and Air Conditioning Qualification
BFO5 UEE33020 Certificate III in Electrical Fitting Qualification
BFP1 UEE22020 Certificate II in Electrotechnology (Career Start) Qualification
BTQ6 UEE22025 Certificate II in Electrotechnology (Career Start) Qualification
BFN0 UEE30820 Certificate III in Electrotechnology Electrician Qualification
BHZ3 UEE62122 Advanced Diploma of Engineering Technology - Electrical Qualification
BIV1 UEE62022 Advanced Diploma of Engineering Technology - Renewable Energy Qualification
BHB7 UET30621 Certificate III in ESI - Distribution Overhead Qualification
BHB5 UET30821 Certificate III in ESI - Distribution Underground Qualification
BHY3 UET40422 Certificate IV in ESI - Network Systems Qualification
BHY4 UET60222 Advanced Diploma of ESI - Power Systems Qualification
BHB6 UET30721 Certificate III in ESI - Rail Traction Qualification
BIA7 UET40522 Certificate IV in ESI - Substations Qualification
BHB8 UET30521 Certificate III in ESI - Transmission Overhead Qualification
BHB4 UET30921 Certificate III in ESI - Very Remote Community Utilities Qualification
AE237 UEESS00170 Install and Modify Performance Data Communication Optical Fibre Cabling Skill Set Skill set
BHE71 22697VIC Certificate IV in Integrated Technologies Accredited course
BHQ3 UEP20222 Certificate II in Remote Area Essential Service Qualification
AE254 UEESS00159 Sustainable - Designer of Grid Connected Photovoltaic Systems Skill Set Skill set