Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Fabricate and install commercial glazing

Fabricate and install commercial glazing

Unit of competency
National Code
LMFGG3017C
State Code
S7833
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
04/10/2011
State Implementation and Classification
Approved Date
08/02/2012
Field of Education
040323 - Glazing
Original Release Date
08/02/2012
Nominal Hours
52
Description
This unit of competency covers the skills and knowledge required to plan, fabricate and install flat glass in commercial shopfronts, doors and windows. Curved glass may also be used.
Notes
Elements and Performance Criteria
1 Identify work requirements
  • 1.1 Work requirements in the form of type of glass, frames and the method of fixing are identified from work instructions
  • 1.2 Occupational health and safety (OHS) requirements for fabrication and installation of commercial glazing, including personal protective equipment, are identified and observed throughout the work
  • 1.3 The process for fabricating and installing commercial flat and/or curved glazing is identified
2 Prepare for work
  • 2.1 Work sequence is planned in a logical order to suit the job and workplace procedures
  • 2.2 Tools, equipment and materials, other than glass and frames, are selected and checked prior to use to ensure they are appropriate for the work, serviceable and in a safe condition
  • 2.3 Type of glass to be fitted and frames are selected to match the customer order
  • 2.4 Glass is checked for type, size and imperfections
  • 2.5 Glass fixing method and appropriate method of glazing are selected
3 Identify site conditions and restraints
  • 3.1 Site safety hazards are recognised and corrective action taken to reduce injury to self and others
  • 3.2 Other on-site difficulties are identified and corrective action taken in accordance with regulations and enterprise agreements
  • 3.3 Special characteristics of the glass aperture are identified in relation to the effect of the glass fitting process on the finished job
  • 3.4 Covering material is applied, where necessary, to protect existing fixtures and fittings
4 Prepare frame
  • 4.1 Frame condition is assessed to ensure suitability for glazing in accordance with customer order and Australian Standards
  • 4.2 Defective frames are reported for repair or replacement in accordance with workplace procedures
  • 4.3 Frame is prepared (if required) to receive glass
  • 4.4 Fixing and sealing materials are prepared by mixing or cutting to length, as appropriate
5 Fit glass
  • 5.1 Glass is fixed to the frame using the selected method and in accordance with recognised Australian and industry standards
  • 5.2 Solvents and sealants are used in accordance with manufacturer recommendations and Australian Standards
  • 5.3 Excess sealing material is removed and the glass and frame are cleaned after fixing
6 Complete work
  • 6.1 Completed installation is checked to ensure compliance with customer requirements, specifications and Australian Standards
  • 6.2 Work area is cleaned and left in a safe condition and rubbish removed from work area and disposed of in accordance with relevant statutory requirements and workplace requirements
  • 6.3 Tools, equipment and materials are cleaned and stored following workplace procedures
  • 6.4 Waste and scrap material are removed for disposal or recycling, as required
  • 6.5 Workplace documentation is completed in accordance with workplace requirements
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Types of glass may include, but are not limited to:
annealed glass
toughened glass
laminated glass
bandit resistant glass
bullet resistant glass and heat reflective glass
Fabrication and installation of commercial glazing covers:
work involving the fabrication, assembly, glazing and installation of framed and/or frameless shopfronts and returns, fixed and operable windows, hinged, pivot, sliding and automatic doors. It may include:
toughened glass assemblies
watertight glazing techniques, including use of silicone
may include balustrading
Personal protective equipment includes:
that prescribed under legislation, regulation and enterprise policies and practices, and may include:
gauntlets
gloves
safety glasses
hard hats
safety footwear
aprons and overalls
Curved glazing may include:
cylindrical and non-cylindrical (or ‘J’) curves used for:
revolving doors
shopfronts
lifts and foyers
partitions
pool surrounds
Workplace procedures may include:

workplace procedures relating to fitting of glass for commercial applications
on-site procedures and regulations relating to the handling and movement of glass
work instructions, including job sheets, cutting lists, plans, patterns, templates, drawings and/or designs
safety standards, including personal protective equipment, OHS regulations and enterprise requirements
Australian Standards:
AS 1228:2006 Glass in buildings - Selection and installation
AS/NZS 4667:2000 Quality requirements for cut-to-size and processed glass
AS 2047:1999 Windows in buildings - Selection and installation
AS/NZS 2208:1996 Safety glazing materials in buildings
AS/NZS 2343:1997 Bullet-resistant panels and elements
AS 3555.1:2003 Building elements - Testing and rating for intruder resistance - Intruder-resistant building panels
Tools and equipment may include:
assembly benches
drop and up-cut saws
pneumatic tools
hydraulic and manual presses
frame and sash tooling
copy routers
end millers
crimpers
electric and pneumatic powered drills and screwdrivers
pop rivet guns
glue guns and general hand tools
Materials may include:
all forms of flat and curved glass and acrylic glazing products
plastic
aluminium
steel
solid timber
gaskets
sealants and adhesives
Glass fixing method covers:
specifications
type of glass and frame
security requirements
sealing methods
Australian Standards
Methods of glazing may include:
pocket
flush
channel
double glazing
Frame preparation may include:
cleaning
surface preparation (if required)
checking size against specification


The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Assessment processes and techniques must be culturally appropriate and appropriate to the language, literacy and numeracy capacity of the candidate and the work being performed.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently:
interpret work order/job instruction and locate and apply relevant information to fabricate and install commercial glazing
apply safe handling requirements for equipment, products and materials, including use of personal protective equipment
follow work instructions, operating procedures and inspection practices to:
minimise the risk of injury to self and others
prevent damage to goods, equipment and products
maintain required product quality
as a minimum:
measure for the installation of flat and curved commercial windows, shopfronts and doors
work from product specification data sheets and/or specified software programs
identify and select product materials that are fit for purpose
fabricate frame and sash components, including cutting, tooling/milling, routing, drilling and/or crimping
identify, select and install component hardware, including weather seals, wheels, stays, hinges and concealed overhead closer (COC) pivots, guides and/or locks
select and cut glass to AS 1228:2006 Glass in buildings - Selection and installation, and AS/NZS 4667:2000 Quality requirements for cut-to-size and processed glass
assemble frames, including glass, gaskets, tapes, sealants, adhesives and fasteners in accordance with AS 2047:1999 Windows in buildings - Selection and installation
install framed and frameless commercial windows
calculate the cost of commercial windows, shopfronts and doors
work effectively with others.
Context of and specific resources for assessment
The application of competency is to be assessed in the workplace or realistically simulated workplace.
Assessment is to occur under standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge, other than confirmatory questions, will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian Standard requirements.
The following resources should be made available:
frames
flat and/or curved glass
fixing materials
sealants
workplace operating procedures and work orders
personal protective equipment
an appropriate work area/site.
Method of assessment
Assessment must satisfy the endorsed Assessment Guidelines of the LMF02 Furnishing Industry Training Package.
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with application of underpinning knowledge.
Assessment methods must be by direct observation of tasks and include questioning on underpinning knowledge to ensure correct interpretation and application.
Assessment may be applied under project-related conditions (real or simulated) and require evidence of process.
Assessment must confirm a reasonable inference that competency is able not only to be satisfied under the particular circumstance, but is able to be transferred to other circumstances.
Assessment may be in conjunction with assessment of other units of competency.
Guidance information for assessment



Replaces
State Code National Code Title Type
W8691 LMFGG3017B Fabricate and install commercial glazing Unit of competency
Replaced By
State Code National Code Title Type
WI499 MSFGG3017 Fabricate and install commercial glazing Unit of competency
State Code National Code Title Type
D675 LMF30611 Certificate III in Glass and Glazing Qualification