Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Evaluate and modify low voltage socket outlets circuits

Evaluate and modify low voltage socket outlets circuits

Unit of competency
National Code
UEEEL0010
State Code
OCA69
TGA Status
Current
DTWD Status
Approved
Current Release Number
2.00
Current Release Date
19/07/2022
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
18
Description
This unit involves the skills and knowledge required to evaluate and modify low voltage (LV) socket outlets circuits.It includes working safely, identifying and repairing/replacing faulty socket outlets, ensuring all work complies with relevant Australian Standards and legislation, and completing work and documenting activities.The skills and knowledge described in this unit require a licence or permit to practice in the workplace where work is carried out on electrical installations which are designed to operate at voltages greater than 50 volt (V) alternating current (a.c.) or 120 V direct current (d.c.). Competency development activities in this unit are subject to regulations directly related to licensing. Where a licence or permit to practice is not held, a relevant contract of training, such as an Australian Apprenticeship, may be required. Additional and/or other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Notes
Elements and Performance Criteria
1 Prepare to work on socket outlet circuits
  • 1.1 Scope of work is obtained from relevant documentation, electrical drawings or relevant person/s
  • 1.2 WHS/OHS requirements and workplace procedures for a given work area are identified and applied
  • 1.3 Hazards are identified, risks are assessed and control measures are implemented
  • 1.4 Advice is sought from work supervisor to ensure the work is coordinated effectively with others
  • 1.5 Sources of materials required for work are determined in accordance with workplace procedures
  • 1.6 Tools, equipment and testing devices required to carry out work are obtained and checked for correct operation and safety
2 Evaluate and modify socket outlet circuits
  • 2.1 Socket outlets and circuits are checked and arrangement identified
  • 2.2 Circuits are checked and isolated in accordance with workplace procedures and regulatory requirements
  • 2.3 The need to test or measure live work is determined in accordance with WHS/OHS requirements and, as necessary, conducted in accordance with workplace procedures
  • 2.4 Fault/s and probable cause/s are identified from measure and calculated values as they apply to socket outlet circuits
  • 2.5 Components are identified and replaced in accordance with manufacturer specifications and industry standards
  • 2.6 Unexpected situations are dealt with safely and with the approval of relevant person/s
3 Complete work and document activities
  • 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
  • 3.2 Worksite is cleaned and made safe in accordance with workplace procedures
  • 3.3 Justification for solutions used to modify circuits and equipment is documented
  • 3.4 Work completion is documented and an appropriate person/s notified in accordance with workplace procedures
No information
No information