Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install, maintain and modify customer premises communications cabling: ACMA Restricted Rule
Install, maintain and modify customer premises communications cabling: ACMA Restricted Rule
Unit of competency
National Code
ICTCBL2136B
ICTCBL2136B
State Code
WI876
WI876
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
15/04/2014
Field of Education
031309 - Communications Equipment Installation And Maintenance
Original Release Date
15/04/2014
Nominal Hours
60
Description
This unit describes the performance outcomes, skills and knowledge required to safely install, maintain and modify the customer premises communications cabling required according to the Australian Communications and Media Authority's (ACMA) ‘Restricted’ Cabling Provider Rule.Restricted cabling is used in typical domestic premises, small offices, home offices and small business premises. Restricted cablers can install cable in large commercial and industrial premises provided the cabling is behind a compliant device and is not via jumperable distributors or patch panels.The Telecommunications Cabling Provider Rules (CPRs) 2000 place various limitations on Restricted cablers. These include a prohibition on them performing cabling work where they may have access to a reticulated electrical supply that exceeds typical domestic single-phase and three-phase electrical supply voltages - nominally 240 volts AC (for single phase) or 415 volts AC (for three-phase).Assessment by a TITAB-registered assessor is recommended.All customer cabling work in the telecommunications, fire, security and data industries must be performed by a registered cabler. All cablers are required to register with an ACMA-accredited registrar.
Notes
Elements and Performance Criteria
1. Work within the constraints imposed by customer premises and ACMA regulatory environment
- 1.1 Prepare for restricted cabling work within the regulatory and cabling environment, cable type, cable identification, termination systems, earthing and protection, records and according to requirements of relevant legislation, codes, regulations and standards
- 1.2 Identify building infrastructure that places critical constraints on cabling
- 1.3 Develop strategies to manage other infrastructure in relation to cabling
- 1.4 Notify appropriate personnel of safety hazards at the cabling work site
2. Manage remote power feed
- 2.1 Identify and avoid the risks posed by contact with remote power feeding services when performing cabling activity
- 2.2 Make site safe by identifying remote power feeding services that operate at above telecommunications network voltage (TNV) inside customer premises
3. Install cables and protective earth wires
- 3.1 Install cables according to manufacturer's application specifications, including tension and bending stress requirements
- 3.2 Identify and avoid sources of possible damage to cable, including hot pipes, sharp edges and cable burn
- 3.3 Allow sufficient excess at cable ends to facilitate termination
- 3.4 Place and secure cable to maintain safety and interference segregation according to legislative and industry standards
- 3.5 Install cable ties with correct tension to prevent cable sheath damage or transmission impairment and trimmed flush to prevent risk of personal damage
- 3.6 Install underground cables to minimum depth of cover and segregation from hazardous electrical and other services according to AS/CA TS009:2013
- 3.7 Install underground cables excluding blown fibre tube systems to incorporate a blocking agent within the cable to prevent the ingress of water
- 3.8 Install aerial cables to minimum clearance, segregation from hazardous electrical and other services and minimum height requirements according to AS/CA TS009:2013
- 3.9 Install over-voltage protection devices according to AS/CA TS009:2013 to all cable pairs, where required, to suppress voltage surges and protect from earth potential rise (EPR) hazards and protectively earth the devices
- 3.10 Protect earth wire insulation against damage and segregate protective earths according to relevant legislative and industry standards
4. Terminate and test cables and earth wires
- 4.1 Remove cable sheath to allow for correct termination length and without damage to underlying conductors and their insulation
- 4.2 Install NTD terminating modules according to manufacturer specifications and with cable pairs neatly and sequentially fanned for termination
- 4.3 Terminate conductors according to recommended colour code sequence using appropriate termination tools in the manufacturer's specified manner
- 4.4 Earth cable shield, if applicable, to manufacturer specifications, relevant industry codes of practice and AS/CA TS009:2013
- 4.5 Conduct visual inspection to confirm termination colour code sequence has been followed prior to end-to-end testing of wire and pair termination integrity
- 4.6 Terminate earth wires with connectors recommended by manufacturers according to accepted industry codes of practice and AS/CA TS009:2013
- 4.7 Maintain earth wire continuity throughout and observe interface requirements with electrical systems
- 4.8 Test earthing installation for continuity, insulation resistance and conductive resistance according to accepted industry standards, including AS/CA TS009:2013
- 4.9 Confirm compatibility of alterations with existing systems and test new work both in isolation and when integrated with existing systems
5. Inspect cable route to ensure correct separations
- 5.1 Inspect separations along the entirety of the cable route and rectify separations that do not comply with regulations
- 5.2 Install barriers to achieve separations where sufficient spatial separation cannot be met
6. Create records
- 6.1 Provide the client with a job sign-off and telecommunications cabling advice form, at the completion of each cabling task
- 6.2 Complete NTD record cards for the work undertaken
7. Monitor work activity
- 7.1 Supervise cablers not holding appropriate registration for the task to ensure cabling activity is according to legislative requirements for safety and network integrity, including AS/ACIF S008:2006 and AS/CA TS009:2013
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Restricted cabling work refers to:
aerial and underground cabling work on private property
cabling work that is performed only in relation to a customer’s premises
customer cabling that terminates directly at the network boundary on a socket or network termination device.
Regulatory environment refers to:
accredited registrars and registration
ACMA
Certified Components List
Communications Alliance
labelling requirements
Telecommunications Act 1997.
Cabling environment may refer to:
indoor environments, including concealed locations:
ceilings and false ceilings
internal wall space
modular workstations
under floor
outdoor environments, including cable installations:
aerial telecommunications cabling for restricted cabling work, which does not include installations on poles shared with low voltage (LV) or high voltage (HV) electrical power cables or terminations
external walls
underground cabling in an exclusive trench or shared trench with electrical LV cables and other utilities.
Cable type may include:
aerial
coaxial
copper twisted pair
data cables: Category 5, 6, 6A, 7 or 7A
external
indoor
optic fibre cable
underground.
Cable identification refers to:
cable conductor identification codes:
banded
colour coded
lettered
numbered.
Termination systems must include:
network termination device
socket types:
Australian modular socket
Mode 3 alarm socket
United States modular socket.
Note: Jumperable distributors are not included in this requirement.
Earthing and protection must include:
earthing for protection
surge suppression.
Records may include:
NTD record cards
telecommunication cabling advice forms TCA1 and TCA2.
Relevant legislation, codes, regulations and standards may include:
accredited registrars and registration
Australian Communications Industry Forum (ACIF) standards and codes
ACMA
AS/NZS 3000:2007
AS/ACIF S008:2006 and AS/CA TS009:2013
Certified Components List (CCL)
AS Communications Cabling Manual (CCM) - Restricted
labelling
overview of Telecommunications Act 1997.
Building infrastructure may include:
availability and suitability of existing cabling trays and fixing systems
building hazards
elevated working
high voltage (HV) power
restricted access.
Cabling may include:
aerial customer
external customer
indoor customer
underground customer.
Strategies to manage other infrastructure may include:
appropriate separations
correct use of cable trays and support systems
fastening techniques.
Safety hazards may refer to:
access points that may contain:
hazardous light or non-visible laser
radio frequency (RF) emission
electrical supply and areas of earth potential rise (EPR) that require mandatory separation from communications cable
hazardous conduit as according to AS 1345:1995 conduit colours associated with a hazardous service.
Termination may include:
Australian modular socket
Ethernet connectors terminated at both ends of an Ethernet cable and tested
Mode 3 alarm socket
NTD
United States modular socket
Note: Jumperable distributors are not included in this requirement.
Separations refer to:
correct separations between communications cable and other services:
LV
HV single core
HV multi-core
open terminations
separations covered by AS/CA TS009:2013.
Restricted cabling work refers to:
aerial and underground cabling work on private property
cabling work that is performed only in relation to a customer’s premises
customer cabling that terminates directly at the network boundary on a socket or network termination device.
Regulatory environment refers to:
accredited registrars and registration
ACMA
Certified Components List
Communications Alliance
labelling requirements
Telecommunications Act 1997.
Cabling environment may refer to:
indoor environments, including concealed locations:
ceilings and false ceilings
internal wall space
modular workstations
under floor
outdoor environments, including cable installations:
aerial telecommunications cabling for restricted cabling work, which does not include installations on poles shared with low voltage (LV) or high voltage (HV) electrical power cables or terminations
external walls
underground cabling in an exclusive trench or shared trench with electrical LV cables and other utilities.
Cable type may include:
aerial
coaxial
copper twisted pair
data cables: Category 5, 6, 6A, 7 or 7A
external
indoor
optic fibre cable
underground.
Cable identification refers to:
cable conductor identification codes:
banded
colour coded
lettered
numbered.
Termination systems must include:
network termination device
socket types:
Australian modular socket
Mode 3 alarm socket
United States modular socket.
Note: Jumperable distributors are not included in this requirement.
Earthing and protection must include:
earthing for protection
surge suppression.
Records may include:
NTD record cards
telecommunication cabling advice forms TCA1 and TCA2.
Relevant legislation, codes, regulations and standards may include:
accredited registrars and registration
Australian Communications Industry Forum (ACIF) standards and codes
ACMA
AS/NZS 3000:2007
AS/ACIF S008:2006 and AS/CA TS009:2013
Certified Components List (CCL)
AS Communications Cabling Manual (CCM) - Restricted
labelling
overview of Telecommunications Act 1997.
Building infrastructure may include:
availability and suitability of existing cabling trays and fixing systems
building hazards
elevated working
high voltage (HV) power
restricted access.
Cabling may include:
aerial customer
external customer
indoor customer
underground customer.
Strategies to manage other infrastructure may include:
appropriate separations
correct use of cable trays and support systems
fastening techniques.
Safety hazards may refer to:
access points that may contain:
hazardous light or non-visible laser
radio frequency (RF) emission
electrical supply and areas of earth potential rise (EPR) that require mandatory separation from communications cable
hazardous conduit as according to AS 1345:1995 conduit colours associated with a hazardous service.
Termination may include:
Australian modular socket
Ethernet connectors terminated at both ends of an Ethernet cable and tested
Mode 3 alarm socket
NTD
United States modular socket
Note: Jumperable distributors are not included in this requirement.
Separations refer to:
correct separations between communications cable and other services:
LV
HV single core
HV multi-core
open terminations
separations covered by AS/CA TS009:2013.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
complete a cabling installation and termination:
three different types of telephone sockets:
Australian modular socket
Mode 3 alarm socket
United States modular socket
one NTD
one alarm panel, including completion of a TCA compliance form and NTD records
one Ethernet cable
apply cable conductor identification codes
conduct and interpret cable test results
interpret and apply standards and regulations
comply with all related OHS requirements and work practices.
Context of and specific resources for assessment
Assessment must ensure:
a site on which communications cabling activities may be carried out
use of cabling and field equipment currently used in industry
licensing requirements and other site-related documentation.
Method of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
direct observation of the candidate undertaking cabling installations and tests, and applying cable conductor identification codes
oral or written questioning to assess knowledge of test results, standards requirements and specific technical procedures.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended, for example:
ICTCBL2137B Install, maintain and modify customer premises communications cabling: ACMA Open Rule.
Aboriginal people and other people from a non-English speaking background may have second language issues.
Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.
In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.
Where applicable, physical resources should include equipment modified for people with special needs.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
complete a cabling installation and termination:
three different types of telephone sockets:
Australian modular socket
Mode 3 alarm socket
United States modular socket
one NTD
one alarm panel, including completion of a TCA compliance form and NTD records
one Ethernet cable
apply cable conductor identification codes
conduct and interpret cable test results
interpret and apply standards and regulations
comply with all related OHS requirements and work practices.
Context of and specific resources for assessment
Assessment must ensure:
a site on which communications cabling activities may be carried out
use of cabling and field equipment currently used in industry
licensing requirements and other site-related documentation.
Method of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
direct observation of the candidate undertaking cabling installations and tests, and applying cable conductor identification codes
oral or written questioning to assess knowledge of test results, standards requirements and specific technical procedures.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended, for example:
ICTCBL2137B Install, maintain and modify customer premises communications cabling: ACMA Open Rule.
Aboriginal people and other people from a non-English speaking background may have second language issues.
Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.
In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.
Where applicable, physical resources should include equipment modified for people with special needs.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| D3313 | ICTCBL2136A | Install, maintain and modify customer premises communications cabling: ACMA Restricted Rule | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AWE83 | ICTCBL236 | Install, maintain and modify customer premises communications cabling: ACMA Restricted Rule | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J818 | ICT30613 | Certificate III in Broadband and Wireless Networks | Qualification |
| J814 | ICT30113 | Certificate III in Broadband and Wireless Networks Technology | Qualification |
| AVY7 | ICT40215 | Certificate IV in Information Technology Support | Qualification |
| AWB0 | ICT30115 | Certificate III in Information, Digital Media and Technology | Qualification |
| J600 | ICT20613 | Certificate II in National Broadband Network Construction | Qualification |
| J811 | ICT20213 | Certificate II in Telecommunications | Qualification |
| J817 | ICT30413 | Certificate III in Telecommunications Digital Reception Technology | Qualification |
| J813 | ICT20413 | Certificate II in Telecommunications Digital Reception Technology | Qualification |
| J599 | ICT20513 | Certificate II in Telecommunications Fixed Wireless and Rigging Installation | Qualification |
| J820 | ICT40613 | Certificate IV in Telecommunications Networks Technology | Qualification |
| J819 | ICT40313 | Certificate IV in Telecommunications Radio Communications | Qualification |