Qualification Outline
22/07/2026 12:38 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Certificate IV in Energy Efficiency and Assessment
Certificate IV in Energy Efficiency and Assessment
UEE43120
BFM7
Replaced
Replaced
National Endorsed, State Implementation and Classification
Releases
| Release Version | Release Date | TGA Status | DTWD Status |
|---|---|---|---|
| 2.00 | 24/10/2022 | Current | Approved |
| 1.00 | 05/10/2020 | Replaced | Approved |
Description
This qualification provides competencies to conduct a residential, office and retail dwellings residential and small-medium enterprises (SME) energy audit and to develop energy efficient strategies to reduce energy use in a range of energy services.
The qualification also addresses the environmental and legislative contexts with the fundamental energy audit methodology to develop the initiative and solutions of sustainability and financial viability.
No licensing, legislative or certification requirements apply to this qualification at the time of publication.
Schedule
Packaging Rules
A total of 440 weighting points comprising:- 180 core weighting points listed below; plus
- 260 general elective weighting points from the general elective units listed below.
Choose a total of 260 weighting points elective units from the list below, of which between 0 and 120 weighting points can be taken from Group A; between 0 and 120 weighting points can be taken from Group B; and between 140 and 260 weighting points can be taken from Group C (or all electives units of 260 weighting points can be taken from Group C).
Up to 120 weighting points of the general elective units Group A , may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided that selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC).
There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume.
Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with.
1. Core Units
All core units must be completed.
| State Code | National Code | Title | Hours | Type |
|---|---|---|---|---|
| OCC47 | UEERE0005 | Assess energy loads and uses for energy efficiency in residential, office and retail premises | 36 | Unit of competency |
| OCB37 | UEECD0010 | Compile and produce an energy sector detailed report | 54 | Unit of competency |
| OBZ84 | UEERE0014 | Develop strategies to address sustainability issues for electrical installations | 18 | Unit of competency |
| OCA29 | UEERE0015 | Implement and monitor energy sector environmental and sustainable policies and procedures | 18 | Unit of competency |
| OCA17 | UEECD0024 | Implement and monitor energy sector WHS policies and procedures | 18 | Unit of competency |
| OCB19 | UEECD0027 | Participate in development and follow a personal competency development plan | 18 | Unit of competency |
2. Group A: Imported and Common Elective Units
Between 0 and 120 weighting points can be taken from Group A.
Please refer to the packaging rules for the full details of available options.
| State Code | National Code | Title | Hours | Type |
|---|---|---|---|---|
| OBY09 | UEECD0056 | Apply methods to maintain currency of industry developments | 18 | Unit of competency |
| OBX53 | UEECD0011 | Comply with scheduled and preventative maintenance program processes | 18 | Unit of competency |
| OCD34 | BSBOPS203 | Deliver a service to customers | 40 | Unit of competency |
| OBY02 | UEECO0002 | Maintain documentation | 18 | Unit of competency |
| OBU39 | ICTICT214 | Operate application software packages | 60 | Unit of competency |
| OCA56 | UEECD0035 | Provide basic instruction in the use of electrotechnology apparatus | 18 | Unit of competency |
| OBY92 | UEECO0015 | Provide quotations for installation or service jobs | 18 | Unit of competency |
| OBY79 | UEECO0017 | Source and purchase material/parts for installation or service jobs | 18 | Unit of competency |
3. Group B: Qualification Elective Units
Between 0 and 120 weighting points can be taken from Group B.
Please refer to the packaging rules for the full details of available options.
| State Code | National Code | Title | Hours | Type |
|---|---|---|---|---|
| OCB17 | UEEIC0011 | Develop electrical integrated systems | 18 | Unit of competency |
| OEE77 | UEEEL0078 | Install and commission whole current electricity meters | 18 | Unit of competency |
| OBX97 | UEEDV0005 | Install and maintain cabling for multiple access to telecommunication services | 72 | Unit of competency |
| OBY98 | UEEIC0024 | Plan the electrical installation of integrated systems | 18 | Unit of competency |
| OCA35 | UEEEL0016 | Provide advice on effective and energy efficient lighting products | 18 | Unit of competency |
| OBY73 | UEEEL0061 | Provide advice on the application of energy efficient lighting for ambient and aesthetic effect | 18 | Unit of competency |
| OCA63 | UEEEL0022 | Supply effective and efficient lighting products for domestic and small commercial applications | 36 | Unit of competency |
| OBZ69 | UEECS0033 | Use engineering applications software on personal computers | 36 | Unit of competency |
4. Group C: Qualification Elective Units
Between 140 and 260 weighting points can be taken from Group C; or all 260 weighting points can be taken from Group C.
Please refer to the packaging rules for the full details of available options.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| A153 | UEE43111 | Certificate IV in Energy Efficiency and Assessment | Qualification |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| BIV5 | UEE43322 | Certificate IV in Electrical - Renewable Energy | Qualification |
No information
Entry Requirements
The entry requirement for this qualification is:
UEE30820 Certificate III in Electrotechnology Electrician
or
a current 'Unrestricted Electricians Licence' or its equivalent issued in an Australian state or territory.